Application of Sub-Miniature Fission Chamber Neutron Detector for Neutron Flux Measurement at the RSG-GAS Reactor: Foil Activation Benchmarking
Atom Indonesia · 26.02.2026 · 52 (1) · 1-13
DOI: 10.55981/aij.2026.1768 ↗Kurz gefasst
Fachartikel in der Zeitschrift Atom Indonesia, online erschienen am 26.02.2026. Verfasst von R. Gusman und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Accurate neutron flux measurement is essential for reactor characterization and utilization. At the RSG-GAS reactor, previous flux measurements relied on the foil activation method. While this method provides high accuracy, it lacks real-time capability due to its requirement for irradiation, post-irradiation cooling, and subsequent gamma spectroscopy for activity assessment. Direct online measurements of thermal neutron flux in the RSG-GAS reactor irradiation positions were performed using a Sub-Miniature Fission Chamber (SMFC) detector, where the flux was determined from the detector's output current proportional to fission events. This approach offers a viable alternative to the conventional foil activation technique by eliminating its time-consuming process and multiple uncertainty sources. After applying a correction factor obtained from gold foil activation reference measurements and the combined measurement uncertainty was quantified as ± 4.0%, results showed an axial flux distribution peaking at 200 mm height from the bottom of the core with maximum values of 4.997 x 1012 ± 0.199 x 1012 n/cm².s at central iradiation position (CIP E7), 6.212 x 1012 ± 0.248 x 1012 n/cm².s at iradiation position (IP B6), and 2.096 x 1012 ± 0.083x1012 n/cm².s at reflector element with plug (BS+ A2) under 200 kW operation. Radial mapping at 600 mm height from the bottom of the core revealed a maximum flux of 1.230 x 1012 ± 0.049 x 1012 n/cm².s at IP (G7). These results demonstrate that the Sub-Miniature Fission Chamber (SMFC) enables real-time neutron flux monitoring and provides a viable alternative to the conventional foil activation technique.
Zitieren
APA
Gusman, R., Agung, A., Subekti, R. M., Iswahyudi, F. N., Susanti, F., & Pinem, S. (2026). Application of Sub-Miniature Fission Chamber Neutron Detector for Neutron Flux Measurement at the RSG-GAS Reactor: Foil Activation Benchmarking. Atom Indonesia, 52(1), 1-13. https://doi.org/10.55981/aij.2026.1768
Vancouver
Gusman R, Agung A, Subekti RM, Iswahyudi FN, Susanti F, Pinem S. Application of Sub-Miniature Fission Chamber Neutron Detector for Neutron Flux Measurement at the RSG-GAS Reactor: Foil Activation Benchmarking. Atom Indonesia. 2026;52(1):1-13. doi:10.55981/aij.2026.1768
BibTeX
@article{Gusman2026,
author = {Gusman, R. and Agung, A. and Subekti, R. M. and Iswahyudi, F. N. and Susanti, F. and Pinem, S.},
title = {Application of Sub-Miniature Fission Chamber Neutron Detector for Neutron Flux Measurement at the RSG-GAS Reactor: Foil Activation Benchmarking},
journal = {Atom Indonesia},
year = {2026},
volume = {52},
number = {1},
pages = {1--13},
doi = {10.55981/aij.2026.1768}
}
EUVIMED