Development of a miniature cylindrical parallel-plate avalanche ionization chamber for neutron shielding integral experiments
International Journal of Modern Physics E · 2026-09 · 35 (09)
DOI: 10.1142/s0218301326500370 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Modern Physics E, online erschienen am 21.05.2026. Verfasst von Deng-Hui Wang und 5 weiteren Autor:innen. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
The shielding integral experiment in fission neutronics using a [Formula: see text]Cf neutron source is one of the crucial methods for verifying and evaluating nuclear data quality. At high counting rates, diamond detectors tend to exhibit reduced fission fragment counting rates due to lattice damage. Although traditional parallel-plate ionization chambers have excellent radiation resistance, they suffer from inadequate timing resolution. To overcome these drawbacks, a compact cylindrical parallel-plate avalanche ionization chamber (CPPAC) was developed in this work, with a height of 25[Formula: see text]mm and a diameter of 29[Formula: see text]mm, that can be embedded in test samples. With the fission source closely attached to the electrode film, the detector achieves improved spatial detection efficiency while satisfying the requirements of high counting rates. This detector has a plateau length of approximately 70[Formula: see text]V and a plateau slope of 10.6% per 100[Formula: see text]V. By virtue of the stable gas supply and the low-pressure operating design of the CPPAC, the system achieves a time resolution of 346[Formula: see text]ps. Under the actual operating conditions for fission fragments, the measured timing resolution of the detector is 3.28[Formula: see text]ns (FWHM). During a 34-day test with a [Formula: see text]Cf source, the detector maintained a stable counting rate of 3000 cps, with a daily attenuation rate of approximately 0.389%. The detector exhibits good long-term operational stability over 34 consecutive days of neutron spectrum measurements, with no significant performance degradation observed, providing a reliable experimental basis for studies on sustained operational stability.
Zitieren
APA
Wang, D., Xu, K., Zhang, S., Xu, H., Ma, P., & Wang, J. (2026). Development of a miniature cylindrical parallel-plate avalanche ionization chamber for neutron shielding integral experiments. International Journal of Modern Physics E, 35(09). https://doi.org/10.1142/s0218301326500370
Vancouver
Wang D, Xu K, Zhang S, Xu H, Ma P, Wang J. Development of a miniature cylindrical parallel-plate avalanche ionization chamber for neutron shielding integral experiments. International Journal of Modern Physics E. 2026;35(09). doi:10.1142/s0218301326500370
BibTeX
@article{Wang2026,
author = {Wang, Deng-Hui and Xu, Kuo-Zhi and Zhang, Shi-Yu and Xu, Hao-Jie and Ma, Peng and Wang, Jian-Song},
title = {Development of a miniature cylindrical parallel-plate avalanche ionization chamber for neutron shielding integral experiments},
journal = {International Journal of Modern Physics E},
year = {2026},
volume = {35},
number = {09},
doi = {10.1142/s0218301326500370}
}
EUVIMED