EUVIMEDEUVIMED entdecken
Crossref

Incorporation of graphene oxide into a zinc oxide–eugenol-based endodontic sealer: effect on setting time and exploratory surface characterization by SEM with AI-assisted segmentation

Milene Rodrigues de Souza, Marcella Maria Pinna Lopes, Maurício Magalhães de Paiva, Fernanda Cristina de Souza Coelho dos Santos, Francisco Luiz Correa Rangel, Alexandre Antunes Ribeiro, Fabiano Luis Heggendorn

Revista Caribeña de Ciencias Sociales · 13.11.2026 · 15 (7) · e5021

DOI: 10.55905/rcssv15n7-010 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Caribeña de Ciencias Sociales, online erschienen am 13.11.2026. Verfasst von Milene Rodrigues de Souza und 6 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the effect of incorporating graphene oxide (GO) into Endofill, a zinc oxide–eugenol-based endodontic sealer, on setting time, and to characterize its surface microstructure using artificial intelligence-assisted image processing. Materials and Methods: Eighty-four specimens (n = 21/group) were allocated into four groups: pure Endofill (G1, control) and Endofill incorporated with 0.1% (G2), 0.3% (G3), and 0.5% (G4) GO (w/w). Setting time was determined with a Vicat apparatus according to ISO 6876:2012 and compared using the Kruskal-Wallis and Dunn-Bonferroni tests (α = 0.05). Surfaces were analyzed by FEG-SEM (20,000× and 50,000×), and the micrographs were processed in a semi-automated workflow (Fiji and Python), with grain segmentation performed by the Segment Anything Model 2 from operator-placed prompts, to obtain surface microporosity, grain density, and grain size.

Results

G1 showed the longest setting time; all GO groups exhibited significantly shorter setting times (p < 0.0001), with a mean reduction of 38.9% to 45.7% and no difference among concentrations. G3 and G4 displayed a more compact surface, with discrete, closely packed crystals, and the lowest surface porosity values (18.0% to 26.0%, compared with 24.4% to 47.0% in the control).

Conclusion

GO significantly reduced the setting time of Endofill at concentrations as low as 0.1%, with no dose-dependent effect. The 0.3% and 0.5% concentrations were associated with a more compact and less porous surface microstructure, a descriptive finding that requires confirmation with a larger number of specimens.

Zitieren

APA

Souza, M. R. D., Lopes, M. M. P., Paiva, M. M. D., Santos, F. C. D. S. C. D., Rangel, F. L. C., Ribeiro, A. A., & Heggendorn, F. L. (2026). Incorporation of graphene oxide into a zinc oxide–eugenol-based endodontic sealer: effect on setting time and exploratory surface characterization by SEM with AI-assisted segmentation. Revista Caribeña de Ciencias Sociales, 15(7), e5021. https://doi.org/10.55905/rcssv15n7-010

Vancouver

Souza MRD, Lopes MMP, Paiva MMD, Santos FCDSCD, Rangel FLC, Ribeiro AA, et al. Incorporation of graphene oxide into a zinc oxide–eugenol-based endodontic sealer: effect on setting time and exploratory surface characterization by SEM with AI-assisted segmentation. Revista Caribeña de Ciencias Sociales. 2026;15(7):e5021. doi:10.55905/rcssv15n7-010

BibTeX
@article{Souza2026,
  author = {Souza, Milene Rodrigues de and Lopes, Marcella Maria Pinna and Paiva, Maurício Magalhães de and Santos, Fernanda Cristina de Souza Coelho dos and Rangel, Francisco Luiz Correa and Ribeiro, Alexandre Antunes and Heggendorn, Fabiano Luis},
  title = {Incorporation of graphene oxide into a zinc oxide–eugenol-based endodontic sealer: effect on setting time and exploratory surface characterization by SEM with AI-assisted segmentation},
  journal = {Revista Caribeña de Ciencias Sociales},
  year = {2026},
  volume = {15},
  number = {7},
  pages = {e5021},
  doi = {10.55905/rcssv15n7-010}
}
Kostenlos starten →