Comparative Study of Different Concentration of Trypan Blue for Staining of Capsule in Mature Cataract using RGB Scale in “Adobe Photoshop Image Reader”
The Internet Journal of Ophthalmology and Visual Science · 2010
DOI: 10.5580/17e8 ↗At a glance
Journal article in The Internet Journal of Ophthalmology and Visual Science, 2010.
Abstract (original language)
Satisfactory capsulorhexis is essential in modern small incision cataract surgery. Visualization of capsule in mature cataract is difficult so staining of capsule with dye is required. Trypan blue is most commonly used dye. Carcinogenic effect of trypan blue is proved in animal study. Aim of this study was to determine minimum concentration of trypan blue that stains the anterior capsule.
Methods
The study was conducted in 50 patients with senile mature cataract. Capsular staining was done with different concentration of trypan blue (Group A 0.06%, Group B 0.03%, Group C 0.015%, Group D 0.0075% and Group E 0.00375%) to enhance visualization of capsule for rhexis in cataract surgery. Comparative study of blueness of dye with different concentration was done by RGB scale values in “Adobe Photoshop image reader” Software (Version-7).
Results
Trypan blue stains the capsule satisfactorily in group A, B and C. In group D and E capsular staining was not satisfactory.
Conclusion
Concentrations of 0.03% and 0.015% were as effective as 0.06% to stain the capsule. Concentration of 0.0075% and 0.00375% could not stain the capsule.
Cite
APA
(2010). Comparative Study of Different Concentration of Trypan Blue for Staining of Capsule in Mature Cataract using RGB Scale in “Adobe Photoshop Image Reader”. The Internet Journal of Ophthalmology and Visual Science. https://doi.org/10.5580/17e8
Vancouver
Comparative Study of Different Concentration of Trypan Blue for Staining of Capsule in Mature Cataract using RGB Scale in “Adobe Photoshop Image Reader”. The Internet Journal of Ophthalmology and Visual Science. 2010. doi:10.5580/17e8
BibTeX
@article{euvimed2010,
title = {Comparative Study of Different Concentration of Trypan Blue for Staining of Capsule in Mature Cataract using RGB Scale in “Adobe Photoshop Image Reader”},
journal = {The Internet Journal of Ophthalmology and Visual Science},
year = {2010},
doi = {10.5580/17e8}
}
EUVIMED