EUVIMEDDescubrir EUVIMED
Crossref

A Modular VME Or IBM PC Based Data Acquisition System For Multi-Modality PET/CT Scanners Of Different Sizes And Detector Types

The Internet Journal of Medical Technology · 2003

DOI: 10.5580/124c ↗

At a glance

Journal article in The Internet Journal of Medical Technology, 2003.

ResumenDatos bibliográficosCiteRelated studies

Abstract (original language)

A modular, digital system, fully programmable and scalable for a multi-modality, open (to accommodate claustrophobic or overweight patients, with the option of closing the detector, to increase efficiency), 3-D Complete Body Scan (3D-CBS) utilizing both Positron Emission Tomography (PET) and Computed Tomography (CT) in one unit with no moving parts, has been designed for VME and IBM-PC based platforms.This device fully exploits the double photon emission and allows for: annual whole-body screening for cancer and other systemic anomalies; only 1/30 the radiation dosage; a reduction in scan time to 4 minutes for an axial Field of View (FOV) of 137.4 cm as opposed to 55 minutes for an axial FOV of 70 cm; a decrease in examination cost by 90%; an increase in sensitivity, providing physicians with additional clinical information on a specific organ or area and contribute to the specificity in detecting and assessing cancer.These advantages allow for early detection --the best way to defeat cancer.The system collects digital data from multiple electronic channels.Each electronic channel carries the information (64-bit) of all sensors included in a given view angle of the detector.The 64-bits data packets acquired at 20 MHz by each channel with zero dead-time are correlated with neighboring information and processed in real time by a 3D-Flow DSP to improve the signal-to-noise ratio and extract and measure particle properties, resulting in the identification of the particles' position, accurate energy measurement, Depth of Interaction (DOI), and the timing measurements.A thorough real-time algorithm that best identifies the photons can be executed because the 3D-Flow sequentially-implemented, parallel architecture (SIPA) allows for processing time to be extended in a pipeline stage beyond the time interval between two consecutive input data.Very low power consumption drivers drive short, equal-length PCB traces between 3D-Flow chips, solving the problem of signal skew, ground bounce, cross-talk and noise.The electronics validates and separates events from the different modalities (PET/CT); PET events are checked for coincidences using a circuit sensitive to radiation activity rather than the number of detector elements.Both PET and CT examinations occur at the same time in a stationary bed position using a detector with a long axial FOV, avoiding motion artifacts, increasing throughput, reducing examination cost, reducing radiation to patients, increasing resolution, improving data quality, and reducing erroneous readings (false positives).The saturation of the electronics of current PET is eliminated by using a system with an input bandwidth of 35 billion events per second distributed over 1,792 channels.The output bandwidth is selectable to sustain the activity generated by the maximum radiation that a PET/CT should ever receive.The overall events are gathered by IBM PC or VME CPU board, formatted and sent to the image processing workstation.The entire system can be simulated from top level to gate level before construction.Figure 1.Differences between the current Positron Emission Tomography (PET) and the 3-D Complete Body Scan -3D-CBS (PET Section) FOV 15-25 cm Almost all photons are lost Photons lost FOV 120-160 cm Fewer photons lost HEAD RING TORSO RING Claustrophobic or Overweight Normal weight and NOT claustrophobic Current PET devices have not been widely used during the past 25 years because they: -do not fully exploit the double photon emission phenomenon -use electronics that saturate, which prevents an increase in the FOV for a cost-effective PET.-Only ~ 2 out of 10,000 photons captured -~ 55 minutes to scan 70 cm FOV -Low data quality and resolution High radiation dosage, high examination cost -Annual examination is hazardous !The 3-D Complete Body Scan -3D-CBS is based on the new 3D-Flow architecture that does not saturate, allowing it to capture more photons if used on the current PET (short FOV) and to extend the FOV for a cost-effective 3D-CBS (PET and CT).-~ 1 out of 10 photons captured -Only ~ 4 minutes to scan 140 cm FOV (PET photons) -Good image quality (avoids "false positives") Only 1/30 the radiation dosage, lower examination cost -Permits annual examination !

Cite

APA

(2003). A Modular VME Or IBM PC Based Data Acquisition System For Multi-Modality PET/CT Scanners Of Different Sizes And Detector Types. The Internet Journal of Medical Technology. https://doi.org/10.5580/124c

Vancouver

A Modular VME Or IBM PC Based Data Acquisition System For Multi-Modality PET/CT Scanners Of Different Sizes And Detector Types. The Internet Journal of Medical Technology. 2003. doi:10.5580/124c

BibTeX
@article{euvimed2003,
  title = {A Modular VME Or IBM PC Based Data Acquisition System For Multi-Modality PET/CT Scanners Of Different Sizes And Detector Types},
  journal = {The Internet Journal of Medical Technology},
  year = {2003},
  doi = {10.5580/124c}
}
Start for free →