Neonatal Subgaleal Hemorrhage Following Vacuum Extraction Delivery
The Internet Journal of Pediatrics and Neonatology · 2005
DOI: 10.5580/122c ↗At a glance
Journal article in The Internet Journal of Pediatrics and Neonatology, 2005.
Abstract (original language)
A rare complication of vacuum extraction delivery is subgaleal hemorrhage which may be associated with significant morbidities such as anemia, hypotension, persistent metabolic acidosis and hyperbilirubinemia.
Background
Instruments such as vacuum extractors and forceps are used in ten percent of all vaginal deliveries. Currently, in the United States, the use of vacuum extractors is twice as frequent as that of forceps. A rare, but potentially lethal complication of vacuum extraction deliveries is subgaleal hemorrhage (SGH). This potentially lethal complication of vacuum extraction vaginal delivery is frequently unrecognized or incorrectly diagnosed. More importantly, the pediatric literature in the United States is devoid of a systematic reports and review of this not very infrequent neonatal problem.
Methods
Fifteen cases of SGH following vacuum extraction deliveries are presented with detailed descriptions of two cases, one resulting in death and another resulting in long-term morbidity. With this case reports, current literature was reviewed and a detailed description of the instrumentation, frequency of its use, traumatic complications, predisposing risk factors, clinical features of SGH, its recognition, and its differential diagnosis is provided.
Results
SGH was frequently associated with intracranial hemorrhage and/or cephalohematoma making its diagnosis more difficult by the healthcare providers. Moderate to massive size SGH was associated with anemia, metabolic acidosis, hyperbilirubinemia, intracranial hemorrhage, respiratory distress, seizures, shock, and death. In most cases, SGH following vacuum extraction vaginal delivery was not recognized or there were significant delays in correct diagnosis. The delay in correct diagnosis and the institution of early and appropriate treatment may have resulted in significant morbidity and even mortality.
Conclusions
It is recommended that the neonatal healthcare providers should be made aware when vacuum extractors are used, and be familiar with possible complications associated with its use. If vacuum extractor is used, neonates should be frequently evaluated for early diagnosis of SGH, and the institution of early treatment should be implemented with the hope of minimizing neonatal morbidity and mortality.
Cite
APA
(2005). Neonatal Subgaleal Hemorrhage Following Vacuum Extraction Delivery. The Internet Journal of Pediatrics and Neonatology. https://doi.org/10.5580/122c
Vancouver
Neonatal Subgaleal Hemorrhage Following Vacuum Extraction Delivery. The Internet Journal of Pediatrics and Neonatology. 2005. doi:10.5580/122c
BibTeX
@article{euvimed2005,
title = {Neonatal Subgaleal Hemorrhage Following Vacuum Extraction Delivery},
journal = {The Internet Journal of Pediatrics and Neonatology},
year = {2005},
doi = {10.5580/122c}
}
EUVIMED