Background
The role of volar locking plates in the treatment of distal radial fractures is unsettled. The objective of this study is to evaluate the complications of this treatment method in a district general hospital setting.
Methods
We retrospectively reviewed the radiological and clinical records of 52 consecutive patients who were treated using volar locking plates between November 2004 and August 2006.
Results
Forty-eight patients were available for review at an average follow-up of 14 months (6-26 months). Fifteen patients had one or more complications; median nerve compression symptoms (nine patients), hard-ware related complications (four patients), superficial wound infection and stitch abscess (three patients), malunion (two patients), failure of fixation and loss of reduction (two patients) and complex regional pain syndrome (two patients). A total of seven re-operations were performed. Discussion & Conclusions: Due to the high complication rate in this study, we recommend a more reserved attitude toward the use of distal radial volar locking plates.
Cite
APA
(2008). Complications of Volar Locking Plates for Distal Radius Fractures: Experience of a District General Hospital. The Internet Journal of Orthopedic Surgery. https://doi.org/10.5580/1024
Vancouver
Complications of Volar Locking Plates for Distal Radius Fractures: Experience of a District General Hospital. The Internet Journal of Orthopedic Surgery. 2008. doi:10.5580/1024
BibTeX
@article{euvimed2008,
title = {Complications of Volar Locking Plates for Distal Radius Fractures: Experience of a District General Hospital},
journal = {The Internet Journal of Orthopedic Surgery},
year = {2008},
doi = {10.5580/1024}
}
EUVIMED