Evaluation of the dimensional compatibility of bioceramic-impregnated gutta-percha cones with ISO standards

Melis Yılmaz, Celalettin Topbaş, Emre Övsay, Ayfer Atav

International Dental Research · 31.12.2025 · 15 (3) · 159-164

DOI: 10.5577/intdentres.689 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Dental Research, online erschienen am 31.12.2025. Verfasst von Melis Yılmaz und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

This study aimed to comprehensively evaluate the dimensional compatibility of bioceramic-impregnated gutta-percha cones across four ISO sizes (#20, #25, #35, and #45) by measuring their tip diameters (D0) with ISO 6877 size standards using a quantitative, in vitro approach. Methodology: Bioceramic-impregnated gutta-percha cones with four different sizes were selected, and tip diameters (D0) were measured using an endodontic gauge ruler. Groups were #20 (primary), #25 (small), #35 (medium), and #45 (large), each containing 20 gutta-percha samples. All testing was performed in accordance with ISO 6877. Cones were categorized as compliant, undersized, or oversized. A chi-square test (p = 0.74) was conducted to assess intergroup differences.

Results

72.5% of cones met ISO standards, while 27.5% were undersized. No cones were oversized. The rates of compliance across groups varied slightly but not statistically significantly.

Conclusion

While most cones comply with ISO 6877 standards, a notable proportion did not, indicating the need for enhanced manufacturing precision. The gutta-percha used during the cone fit trial may be used for the final obturation without being replaced with a new one from the package until manufacturers ensure comprehensive standardization.

Zitieren

APA

Yılmaz, M., Topbaş, C., Övsay, E., & Atav, A. (2025). Evaluation of the dimensional compatibility of bioceramic-impregnated gutta-percha cones with ISO standards. International Dental Research, 15(3), 159-164. https://doi.org/10.5577/intdentres.689

Vancouver

Yılmaz M, Topbaş C, Övsay E, Atav A. Evaluation of the dimensional compatibility of bioceramic-impregnated gutta-percha cones with ISO standards. International Dental Research. 2025;15(3):159-164. doi:10.5577/intdentres.689

BibTeX
@article{Ylmaz2025,
  author = {Yılmaz, Melis and Topbaş, Celalettin and Övsay, Emre and Atav, Ayfer},
  title = {Evaluation of the dimensional compatibility of bioceramic-impregnated gutta-percha cones with ISO standards},
  journal = {International Dental Research},
  year = {2025},
  volume = {15},
  number = {3},
  pages = {159--164},
  doi = {10.5577/intdentres.689}
}
Kostenlos starten →