EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of 100 μmol mol−1 Cl2 Standard Gas Mixture for Accurate Calibration of Ambient Cl2 Sensors and Stack Emission Monitors

Jinsang Jung, ByungMoon Kim, Sanghyub Oh

Asian Journal of Atmospheric Environment · 2020-06 · 14 (2) · 170-176

DOI: 10.5572/ajae.2020.14.2.170 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Asian Journal of Atmospheric Environment, online erschienen am 01.06.2020. Verfasst von Jinsang Jung und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Korea Research Institute of Standards and Science.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To accurately measure Cl 2 mixing ratio using stack emission monitors and leak monitoring sensors in a workplace, it is essential calibrating monitors and sensors periodically using a Cl 2 standard gas mixture. Because there is no reliable analytical technique for Cl 2 , an international standard for high-pressure Cl 2 gas mixtures has not been established. A novel approach for the quantification of Cl 2 was developed using quadrupole mass spectrometry (QMS) with an expanded uncertainty of 0.7 μmol mol −1 . A 100 μmol mol −1 chlorine (Cl 2 )/N 2 gas mixture was produced through a two-step procedure involving dilution of Cl 2 with N 2 in high-pressure aluminum cylinders. To check the consistency between 100 μmol mol −1 Cl 2 gas mixtures in different cylinders, Cl 2 gas mixtures were quantified using the QMS based approach. It was found that four cylinders of 100 μmol mol −1 Cl 2 gas mixtures prepared in 2016 agreed within 0.7 μmol mol −1 . The long-term stability of 100 μmol mol −1 Cl 2 gas mixtures was assessed through changes in the Cl 2 mixing ratio over a one-year. It was found that the 100 μmol mol −1 Cl 2 gas mixture was stable within ±0.7 μmol mol −1 over one year. Finally, 100 μmol mol −1 Cl 2 /N 2 gas mixture was successfully developed in a high pressure cylinder with an expanded uncertainty of 2.0 μmol mol −1 ( k = 2; 95% confidence level).

Förderung

  • Korea Research Institute of Standards and Science

Zitieren

APA

Jung, J., Kim, B., & Oh, S. (2020). Development of 100 μmol mol−1 Cl2 Standard Gas Mixture for Accurate Calibration of Ambient Cl2 Sensors and Stack Emission Monitors. Asian Journal of Atmospheric Environment, 14(2), 170-176. https://doi.org/10.5572/ajae.2020.14.2.170

Vancouver

Jung J, Kim B, Oh S. Development of 100 μmol mol−1 Cl2 Standard Gas Mixture for Accurate Calibration of Ambient Cl2 Sensors and Stack Emission Monitors. Asian Journal of Atmospheric Environment. 2020;14(2):170-176. doi:10.5572/ajae.2020.14.2.170

BibTeX
@article{Jung2020,
  author = {Jung, Jinsang and Kim, ByungMoon and Oh, Sanghyub},
  title = {Development of 100 μmol mol−1 Cl2 Standard Gas Mixture for Accurate Calibration of Ambient Cl2 Sensors and Stack Emission Monitors},
  journal = {Asian Journal of Atmospheric Environment},
  year = {2020},
  volume = {14},
  number = {2},
  pages = {170--176},
  doi = {10.5572/ajae.2020.14.2.170}
}
Kostenlos starten →