Journal article in The Eurasia Proceedings of Science, Technology, Engineering and Mathematics, published online on 2026-07-31. Written by Arifa Haryani and 7 co-authors. The full text is freely available (open access, CC BY 4.0).

AbstraktBibliografické údajeCiteRelated studies

Abstract (original language)

The increasing demand for agricultural production requires reliable and non-destructive methods for monitoring plant physiological conditions in real time, particularly in controlled environments. Spectral sensing in the visible to near-infrared (VIS–NIR) region offers a promising approach; however, the performance of low-cost sensors is often limited by calibration accuracy, wavelength-dependent sensitivity, and insufficient validation against plant physiological indicators. This study aims to evaluate the performance of a VIS–NIR plant monitoring system based on the AS7265x multispectral sensor in a controlled hydroponic environment. Lettuce (Lactuca sativa L.) was grown under two nutrient concentrations (600 ppm and 1200 ppm), and spectral reflectance data were collected across the 410–760 nm range. Sensor measurements were calibrated and validated against a LI-COR LI-180 reference spectrometer using linear regression, with performance assessed using the coefficient of determination (R²), root mean square error (RMSE), and spectral response consistency. The results show strong calibration performance, with wavelength-specific R² values ranging from 0.9682 to 0.9870 and RMSE values between 0.26965 and 5.19772. Although a systematic offset was observed, the AS7265x sensor preserved key spectral patterns, particularly in the green (510–560 nm) and red-edge (705–730 nm) regions. Differences in nutrient concentration were consistently reflected in both spectral responses and SPAD measurements, indicating sensitivity to plant physiological variations. These findings demonstrate that the AS7265x sensor provides reliable spectral information for relative plant monitoring and has strong potential as a cost-effective tool for plant quality assessment in controlled environments.

Cite

APA

Haryani, A., Nugroho, A. P., Nawi, N. M., Falah, M. A. F., Sutiarso, L., Wiratmoko, A., Dzaky, M. A. F., & Marseno, S. G. (2026). Evaluation of a Plant Quality Monitoring System Based on Visible and Near-Infrared Spectroscopy Sensors in a Controlled Environment. The Eurasia Proceedings of Science, Technology, Engineering and Mathematics, 40((Early Pub)), 211-221. https://doi.org/10.55549/epstem.1445

Vancouver

Haryani A, Nugroho AP, Nawi NM, Falah MAF, Sutiarso L, Wiratmoko A, et al. Evaluation of a Plant Quality Monitoring System Based on Visible and Near-Infrared Spectroscopy Sensors in a Controlled Environment. The Eurasia Proceedings of Science, Technology, Engineering and Mathematics. 2026;40((Early Pub)):211-221. doi:10.55549/epstem.1445

BibTeX
@article{Haryani2026,
  author = {Haryani, Arifa and Nugroho, Andri Prima and Nawi, Nazmi Mat and Falah, Mohammad Affan Fajar and Sutiarso, Lilik and Wiratmoko, Ardan and Dzaky, Muhammad Athala Fawwaz and Marseno, Samuel Gatot},
  title = {Evaluation of a Plant Quality Monitoring System Based on Visible and Near-Infrared Spectroscopy Sensors in a Controlled Environment},
  journal = {The Eurasia Proceedings of Science, Technology, Engineering and Mathematics},
  year = {2026},
  volume = {40},
  number = {(Early Pub)},
  pages = {211--221},
  doi = {10.55549/epstem.1445}
}