EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

ELECTRODIAGNOSTIC REFERENCE VALUES FOR ULNAR MOTOR NERVE CONDUCTION RECORDED FROM THE FLEXOR CARPI ULNARIS MUSCLE

Chanasak Hathaiareerug, Hemmarat Pareesri, Chanwit Phongamwong

Journal of Southeast Asian Medical Research · 2026

DOI: 10.55374/jseamed.v10.310 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Southeast Asian Medical Research, 2026. Verfasst von Chanasak Hathaiareerug und 2 weiteren Autor:innen. Die Arbeit nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Ulnar nerve entrapment at the elbow is the second most common compressive neuropathy of the upper extremity. The flexor carpi ulnaris (FCU) muscle may improve diagnostic accuracy in localizing ulnar neuropathy, particularly when distal recording is not feasible because of severe muscle atrophy.

Objective

The present study aimed to establish the electrodiagnostic reference values for the ulnar nerve recorded at the FCU muscle.

Methods

A total of 73 upper extremities from 44 patients with suspected carpal tunnel syndrome underwent nerve conduction study. For the FCU muscle, the active electrode was placed 10 cm below the medial epicondyle, and the reference electrode was placed at the pisiform bone. The ulnar nerve was stimulated at the wrist, the medial epicondyle, and 10 cm proximal to the medial epicondyle. The recorded parameters included onset latency at the elbow and above the elbow, as well as CMAP amplitude, area, and duration.

Results

The mean DML and CMAP amplitude following stimulation at the medial epicondyle were 2.35 ± 0.35 ms and 8.89 ± 2.84 mV, respectively. The mean NCV across the elbow was 65.12 ± 10.28 m/s.

Conclusion

The upper limit of normal for DML was 3.05 ms, and the lower limit of normal (LLN) for CMAP amplitude was 3.21 mV, both derived using the mean ± 2 SD. In contrast, the LLN for NCV across the elbow was 50.51 m/s, based on the 2.5th percentile.

Zitieren

APA

Hathaiareerug, C., Pareesri, H., & Phongamwong, C. (2026). ELECTRODIAGNOSTIC REFERENCE VALUES FOR ULNAR MOTOR NERVE CONDUCTION RECORDED FROM THE FLEXOR CARPI ULNARIS MUSCLE. Journal of Southeast Asian Medical Research. https://doi.org/10.55374/jseamed.v10.310

Vancouver

Hathaiareerug C, Pareesri H, Phongamwong C. ELECTRODIAGNOSTIC REFERENCE VALUES FOR ULNAR MOTOR NERVE CONDUCTION RECORDED FROM THE FLEXOR CARPI ULNARIS MUSCLE. Journal of Southeast Asian Medical Research. 2026. doi:10.55374/jseamed.v10.310

BibTeX
@article{Hathaiareerug2026,
  author = {Hathaiareerug, Chanasak and Pareesri, Hemmarat and Phongamwong, Chanwit},
  title = {ELECTRODIAGNOSTIC REFERENCE VALUES FOR ULNAR MOTOR NERVE CONDUCTION RECORDED FROM THE FLEXOR CARPI ULNARIS MUSCLE},
  journal = {Journal of Southeast Asian Medical Research},
  year = {2026},
  doi = {10.55374/jseamed.v10.310}
}
Kostenlos starten →