Reference Electrode Position Affects Compound Muscle Action Potential Amplitude in Ulnar Nerve Conduction Studies Recorded From the First Dorsal Interosseous Muscle
Muscle & Nerve · 2026-12 · 74 (6) · 1573-1578
DOI: 10.1002/mus.70415 ↗Kurz gefasst
Fachartikel in der Zeitschrift Muscle & Nerve, online erschienen am 20.09.2026. Verfasst von Ross Penninkilampi und 3 weiteren Autor:innen. Beteiligte Einrichtung: Neurology Department, Concord Repatriation General Hospital, Concord, New South Wales, Australia. Hauptthemen laut MEDLINE: Nerve Conduction Studies, Action Potentials, Ulnar Nerve, Muscle, Skeletal. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
Introduction/Aims Nerve conduction studies (NCSs) of the ulnar nerve recording from the first dorsal interosseous muscle (FDI) are clinically relevant in assessing ulnar neuropathy and the split‐hand index. Reference electrode (E2) position varies across normative datasets, with the base of the thumb favored to avoid an initial positive deflection in the compound muscle action potential (CMAP). While latency effects of E2 position have been described, consequences for CMAP amplitude and area have not been systematically examined in a within‐subject comparison. This study aims to evaluate CMAP parameters in paired ulnar motor NCS recordings from FDI with E2 over the base of the index finger or thumb.
Methods
This retrospective study analyzed 183 ulnar motor NCS recordings from FDI in 155 patients referred for neurophysiological testing. CMAP amplitude, latency, negative peak duration, and area were recorded with E2 positioned at the base of the thumb and then the index finger. Within‐subjects comparison was assessed using paired t ‐tests, with Bland–Altman analysis to assess agreement.
Results
CMAP amplitude was on average 2.8 mV lower with E2 at the thumb than at the index finger (95% CI: −3.1 to −2.4; p < 0.0001), with a corresponding reduction in CMAP area. There was no clinically meaningful effect on latency or peak duration. Bland–Altman analysis showed no proportional bias. In 40% of studies with abnormal CMAP amplitude at the thumb, repositioning E2 to the index finger normalized the amplitude.
Discussion
Reference electrode position substantially affects ulnar FDI CMAP amplitude, with implications for ulnar neuropathy diagnosis and split‐hand index calculation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Neurology Department, Concord Repatriation General Hospital, Concord, New South Wales, Australia.
- Neurology Department, Westmead Hospital, Westmead, New South Wales, Australia.
- Inner West Neurology Neurophysiology Laboratory, Burwood, New South Wales, Australia.
- Sydney Medical School, The University of Sydney, Camperdown, Australia.
ORCID-Profile: Ross Penninkilampi, Con Yiannikas, Matthew Silsby
Zitieren
APA
Penninkilampi, R., Beadon, C., Yiannikas, C., & Silsby, M. (2026). Reference Electrode Position Affects Compound Muscle Action Potential Amplitude in Ulnar Nerve Conduction Studies Recorded From the First Dorsal Interosseous Muscle. Muscle & Nerve, 74(6), 1573-1578. https://doi.org/10.1002/mus.70415
Vancouver
Penninkilampi R, Beadon C, Yiannikas C, Silsby M. Reference Electrode Position Affects Compound Muscle Action Potential Amplitude in Ulnar Nerve Conduction Studies Recorded From the First Dorsal Interosseous Muscle. Muscle & Nerve. 2026;74(6):1573-1578. doi:10.1002/mus.70415
BibTeX
@article{Penninkilampi2026,
author = {Penninkilampi, Ross and Beadon, Catherine and Yiannikas, Con and Silsby, Matthew},
title = {Reference Electrode Position Affects Compound Muscle Action Potential Amplitude in Ulnar Nerve Conduction Studies Recorded From the First Dorsal Interosseous Muscle},
journal = {Muscle & Nerve},
year = {2026},
volume = {74},
number = {6},
pages = {1573--1578},
doi = {10.1002/mus.70415}
}
EUVIMED