EUVIMEDEUVIMED entdecken
Metaanalyse

Efficacy and safety of 6-mm vs 8-mm covered stents for tips creation: A meta-analysis

Muhammad Arsalan, FNU Sawaira, Umna Bhatti, Taimoor Hassan, Shafi Muhammad Shah, Safdar Ullah Dawar, Syed Nouman Ali Shah, Rasheeda Shehroz, Muhammad Mughees, Muhammad Yasir, Madho Mal, Abdul Haseeb Hasan

World Journal of Translational Medicine · 2026

DOI: 10.5528/wjtm.124020 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift World Journal of Translational Medicine, 2026. Verfasst von Muhammad Arsalan und 11 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND Hepatic encephalopathy (HE) remains a major complication of transjugular intrahepatic portosystemic shunt (TIPS) creation, occurring in approximately 30% of patients despite the widespread adoption of polytetrafluoroethylene (PTFE)-covered stents. Stent diameter influences the volume of portal blood diverted to the systemic circulation and may thereby modulate the risk of post-procedural HE. Whether 6-mm covered stents can reduce encephalopathy without compromising hemodynamic efficacy or survival relative to the standard 8-mm configuration is uncertain. AIM To compare the efficacy and safety of 6-mm vs 8-mm covered stents in adults undergoing TIPS for cirrhotic portal hypertension. METHODS A systematic review and meta-analysis was conducted in accordance with PRISMA 2020 guidance. MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials were searched through the end of 2025. Studies comparing 6-mm and 8-mm PTFE-covered stents for TIPS creation in adults with cirrhotic portal hypertension were eligible. Risk of bias was assessed with RoB 2 for randomised trials and ROBINS-I for non-randomised studies. Pooled risk ratios (RR) and mean differences were estimated under a random-effects model. Certainty of evidence was rated with the Grading of Recommendations, Assessment, Development and Evaluations framework. RESULTS Five studies were included: One randomised controlled trial (Zhang et al ) and four non-randomised cohort studies (Liu et al , Yan et al , Xia et al , Yao et al ), enrolling a combined 2060 patients. The 6-mm stent was associated with a significant reduction in overall HE (RR = 0.56; 95%CI: 0.41-0.75; P = 0.0001; I ² = 0%) and in overt HE (RR = 0.62; 95%CI: 0.41-0.93; P = 0.02; I ² = 54%). Achievement of the target portal pressure gradient below 12 mmHg did not differ significantly between stent diameters (RR = 0.93; 95%CI: 0.83-1.03; P = 0.16; I ² = 0%). Overall survival at 2 years (RR = 1.04; 95%CI: 0.96-1.13; P = 0.32), shunt dysfunction (RR = 0.97; 95%CI: 0.71-1.32; P = 0.83), and variceal rebleeding (RR = 1.28; 95%CI: 0.96-1.69; P = 0.09) were not significantly different. CONCLUSION A 6-mm effective shunt diameter was associated with a lower risk of HE after TIPS than an 8-mm diameter, without a detectable difference in survival, shunt patency, or portal decompression, and with a possible increase in variceal rebleeding. Because the certainty of evidence was low to very low and most data derived from non-randomised studies, these findings are hypothesis-generating and are not sufficient to recommend a preferred stent configuration; individualised consideration is required, particularly for patients at elevated baseline rebleeding risk.

Zitieren

APA

Arsalan, M., Sawaira, F., Bhatti, U., Hassan, T., Shah, S. M., Dawar, S. U., Shah, S. N. A., Shehroz, R., Mughees, M., Yasir, M., Mal, M., & Hasan, A. H. (2026). Efficacy and safety of 6-mm vs 8-mm covered stents for tips creation: A meta-analysis. World Journal of Translational Medicine. https://doi.org/10.5528/wjtm.124020

Vancouver

Arsalan M, Sawaira F, Bhatti U, Hassan T, Shah SM, Dawar SU, et al. Efficacy and safety of 6-mm vs 8-mm covered stents for tips creation: A meta-analysis. World Journal of Translational Medicine. 2026. doi:10.5528/wjtm.124020

BibTeX
@article{Arsalan2026,
  author = {Arsalan, Muhammad and Sawaira, FNU and Bhatti, Umna and Hassan, Taimoor and Shah, Shafi Muhammad and Dawar, Safdar Ullah and Shah, Syed Nouman Ali and Shehroz, Rasheeda and Mughees, Muhammad and Yasir, Muhammad and Mal, Madho and Hasan, Abdul Haseeb},
  title = {Efficacy and safety of 6-mm vs 8-mm covered stents for tips creation: A meta-analysis},
  journal = {World Journal of Translational Medicine},
  year = {2026},
  doi = {10.5528/wjtm.124020}
}
Kostenlos starten →