Assessment of safety and patency of 7-mm covered metal stents for preoperative biliary drainage in pancreatic cancer: Prospective multicenter study
Endoscopy International Open · 13.01.2025 · 13 (CP)
DOI: 10.1055/a-2503-1995 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy International Open, erschienen am 13.01.2025. Verfasst von Hirotoshi Ishiwatari und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Century Medical Corporation.
Abstract (Originalsprache)
For preoperative biliary drainage of pancreatic cancer (PC), a 10-mm diameter metal stent (MS) is commonly used; however, the rate of pancreatitis is high. It is hypothesized that smaller-diameter MS may reduce the rate of pancreatitis. Therefore, we conducted a multicenter prospective study to evaluate the efficacy and safety of 7-mm MS. Patients requiring initial biliary drainage for obstructive jaundice caused by PC and scheduled for surgery from six facilities were included. After endoscopic retrograde cholangiography, a 7-mm MS was placed at the site of biliary obstruction. The primary endpoint was the rate of pancreatitis, and the secondary endpoints included early and late adverse events (AEs). The pancreatitis rate was assumed to be 18% and 5% with 10- and 7-mm MS, respectively; with a power of 80% and one-sided significance level of 10%, the planned enrollment was 38 patients. If pancreatitis occurred in no more than three patients, this indicates that the 7-mm MS effectively reduced incidence of pancreatitis. Overall, 38 patients were enrolled, and 35 patients in whom a 7-mm MS was successfully placed were analyzed. All MS were placed after sphincterotomy. Pancreatitis occurred in four patients (11.4%) and no early AEs were observed. Surgery was performed in 24 patients and late AEs included stent occlusion in eight patients (23%) and cholecystitis in four patients (11%). The 7-mm MS did not reduce incidence of pancreatitis among surgical candidates for PC.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Endoscopy, Shizuoka Cancer Center, Nagaizumi, Japan.
- Department of Gastroenterology, Seirei Hamamatsu Hospital, Hamamatsu, Japan.
- Department of Gastroenterology, Shizuoka General Hospital, Shizuoka, Japan.
- First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan.
- Department of Gastroenterology, Iwata City Hospital, Iwata, Japan.
- Department of Internal Medicine II, Hamamatsu University School of Medicine, Hamamatsu, Japan.
ORCID-Profile: Hirotoshi Ishiwatari, Shinya Kawaguchi, Fumitaka Niiya, Tatsunori Satoh
Förderung
- Century Medical Corporation
Zitieren
APA
Ishiwatari, H., Kobayashi, Y., Kawaguchi, S., Iwashita, T., Kaneko, J., Ito, J., Ishikawa, K., Sato, J., Niiya, F., Endo, S., Satoh, T., Uemura, S., & Mori, K. (2025). Assessment of safety and patency of 7-mm covered metal stents for preoperative biliary drainage in pancreatic cancer: Prospective multicenter study. Endoscopy International Open, 13(CP). https://doi.org/10.1055/a-2503-1995
Vancouver
Ishiwatari H, Kobayashi Y, Kawaguchi S, Iwashita T, Kaneko J, Ito J, et al. Assessment of safety and patency of 7-mm covered metal stents for preoperative biliary drainage in pancreatic cancer: Prospective multicenter study. Endoscopy International Open. 2025;13(CP). doi:10.1055/a-2503-1995
BibTeX
@article{Ishiwatari2025,
author = {Ishiwatari, Hirotoshi and Kobayashi, Yousuke and Kawaguchi, Shinya and Iwashita, Takuji and Kaneko, Junichi and Ito, Jun and Ishikawa, Kazuma and Sato, Junya and Niiya, Fumitaka and Endo, Shinya and Satoh, Tatsunori and Uemura, Shinya and Mori, Keita},
title = {Assessment of safety and patency of 7-mm covered metal stents for preoperative biliary drainage in pancreatic cancer: Prospective multicenter study},
journal = {Endoscopy International Open},
year = {2025},
volume = {13},
number = {CP},
doi = {10.1055/a-2503-1995}
}
EUVIMED