Early Clinical Outcomes, Comfort, and Satisfaction With Customized 3D-Printed PLA Transtibial Sockets: A Prospective Pilot Study
Journal of Applied Nursing and Health · 01.11.2026 · 8 (3) · 2195-2210
DOI: 10.55018/janh.v8i3.755 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Nursing and Health, online erschienen am 01.11.2026. Verfasst von Nur Rachmat und 2 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
Background
Fused Deposition Modeling (FDM) using Polylactic Acid (PLA) may support transtibial socket fabrication, but evidence remains limited regarding short-term patient-centered responses, wear time, and safety. This study evaluated socket comfort, residual-limb pain, satisfaction, wear time, and adverse events over 28 days.
Methods
This single-arm, uncontrolled, pre-experimental repeated-measures pilot study purposively recruited 30 adults with unilateral transtibial amputation in Central Java, Indonesia. The primary outcome was Socket Comfort Score (SCS); secondary outcomes included residual-limb pain, satisfaction with the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST 2.0), wear time, and adverse events. SCS and residual-limb pain were assessed at T0 and days 7, 14, 21, and 28. Inferential analyses used 29 complete cases; descriptive and safety summaries included 30. Friedman and Wilcoxon signed-rank tests were used.
Results
Median SCS increased from 5.3 (interquartile range [IQR] 4.7-6.2) at T0 to 6.1 (IQR 5.4-7.3) at day 28 (W = 60; p < 0.001; r = 0.63). Residual-limb pain decreased from 3.5 (IQR 2.8-4.2) to 3.0 (IQR 1.7-3.8) (W = 58; p < 0.001; r = 0.61). Day-28 QUEST 2.0 satisfaction was 3.98 ± 0.36/5 and wear time was 8.49 ± 1.68 hours/day. Nine participants experienced mild observed clinical adverse events; all resolved with conservative management. Inferential analyses used 29 complete cases, whereas descriptive and adverse-event summaries included all 30 participants.
Conclusion
Customized FDM-printed PLA transtibial sockets demonstrated promising short-term clinical feasibility and tolerability over 28 days, with improved socket comfort, reduced residual-limb pain, substantial wear time, and no observed serious clinical adverse events. These findings do not establish causal effectiveness, superiority, mechanical or structural safety, durability, or long-term safety, and the satisfaction findings require cautious interpretation because a validated Indonesian-language QUEST 2.0 was not available.
Zitieren
APA
Rachmat, N., Syafii, M., & Septiani, A. E. (2026). Early Clinical Outcomes, Comfort, and Satisfaction With Customized 3D-Printed PLA Transtibial Sockets: A Prospective Pilot Study. Journal of Applied Nursing and Health, 8(3), 2195-2210. https://doi.org/10.55018/janh.v8i3.755
Vancouver
Rachmat N, Syafii M, Septiani AE. Early Clinical Outcomes, Comfort, and Satisfaction With Customized 3D-Printed PLA Transtibial Sockets: A Prospective Pilot Study. Journal of Applied Nursing and Health. 2026;8(3):2195-2210. doi:10.55018/janh.v8i3.755
BibTeX
@article{Rachmat2026,
author = {Rachmat, Nur and Syafii, M. and Septiani, Anissa Eka},
title = {Early Clinical Outcomes, Comfort, and Satisfaction With Customized 3D-Printed PLA Transtibial Sockets: A Prospective Pilot Study},
journal = {Journal of Applied Nursing and Health},
year = {2026},
volume = {8},
number = {3},
pages = {2195--2210},
doi = {10.55018/janh.v8i3.755}
}