EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Importance of suture Endobutton augmentation in type 2B clavicle fracture fixation using a locking plate

Hilal Yağar, Ceyhun Çağlar, Zeynel Mert Asfuroğlu, Murat Aydın

Clinics in Shoulder and Elbow · 01.06.2025 · 28 (2) · 163-169

DOI: 10.5397/cise.2025.00038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinics in Shoulder and Elbow, erschienen am 01.06.2025. Verfasst von Hilal Yağar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics and Traumatology, Niğde Ömer Halisdemir University Medical School, Niğde, Türkiye. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Instability in distal clavicle fractures with impaired integrity of the coracoclavicular (CC) ligament poses a serious risk of nonunion, necessitating surgical intervention. Despite a consensus on the need for surgery in cases of unstable distal clavicle fractures, various surgical techniques are available. The aim of this study is to evaluate the radiological and functional outcomes of CC augmentation using the suture Endobutton technique for Neer type 2b clavicle fractures were evaluated.

Methods

In this retrospective study, 42 patients who met the criteria were divided into two groups: group 1 (locking plate with CC augmentation) and group 2 (locking plate without CC augmentation). Demographic data, Constant-Murley score (CMS), union time, range of motion, complications, and implant failures during the follow-up period were recorded.

Results

Among study patients, 13 (31.0%) were female and 29 (69.0%) were male. The mean age was 40.5±11.5 years. Significant differences were found in union time (week) (t(40)=–2.11, P=0.04) and the 6-month CMS (t(40)=4.19, P=0.01). Significant difference was not observed in postoperative complications between the groups (P>0.05).

Conclusions

CC augmentation with a suture Endobutton in type 2b distal clavicle fractures resulted in more favorable short-term functional and radiological outcomes.Level of evidence: III.

Schlagwörter

Stichwörter der Autor:innen

ClavicleLigamentsPostoperative complicationsBone fractures

Autor:innen und Institutionen

  • Department of Orthopedics and Traumatology, Niğde Ömer Halisdemir University Medical School, Niğde, Türkiye.
  • Department of Orthopedics and Traumatology, Yıldırım Beyazıt University Medical School, Ankara, Türkiye.
  • Department of Orthopedics and Traumatology, Mersin University Medical School, Mersin, Türkiye.
  • Department of Orthopedics and Traumatology, Darıca Hospital Park, Kocaeli, Türkiye.

Zitieren

APA

Yağar, H., Çağlar, C., Asfuroğlu, Z. M., & Aydın, M. (2025). Importance of suture Endobutton augmentation in type 2B clavicle fracture fixation using a locking plate. Clinics in Shoulder and Elbow, 28(2), 163-169. https://doi.org/10.5397/cise.2025.00038

Vancouver

Yağar H, Çağlar C, Asfuroğlu ZM, Aydın M. Importance of suture Endobutton augmentation in type 2B clavicle fracture fixation using a locking plate. Clinics in Shoulder and Elbow. 2025;28(2):163-169. doi:10.5397/cise.2025.00038

BibTeX
@article{Yaar2025,
  author = {Yağar, Hilal and Çağlar, Ceyhun and Asfuroğlu, Zeynel Mert and Aydın, Murat},
  title = {Importance of suture Endobutton augmentation in type 2B clavicle fracture fixation using a locking plate},
  journal = {Clinics in Shoulder and Elbow},
  year = {2025},
  volume = {28},
  number = {2},
  pages = {163--169},
  doi = {10.5397/cise.2025.00038}
}
Kostenlos starten →