EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Agreement Between Six Bioelectrical Impedance Analysis Devices and Dual-Energy X-Ray Absorptiometry

Gena Irwin, Ariel Aguiar Bonfim Cruz, Alexa Chandler, C.J. Brush, Ann Frost Brown

Journal of Exercise and Nutrition · 09.09.2025 · 8 (1)

DOI: 10.53520/jen2025.103206 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Exercise and Nutrition, online erschienen am 09.09.2025. Verfasst von Gena Irwin und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Bioelectrical impedance analysis (BIA) is a low-cost, accessible method to assess percent body fat (%BF). Rising recognition of the role of body composition in overall health and disease prevention has led to an increased usage of at-home BIA devices. The purpose of this study was to assess the level of agreement between six BIA devices and dual-energy x-ray absorptiometry (DXA).

Methods

Male (n=42) and female (n=35) participants completed body composition testing on six different BIA devices and a DXA scan Agreement was assessed using intraclass correlation coefficients (ICC) with 95% confidence intervals, Spearman’s correlations, and Bland-Altman analyses to determine limits of agreement (LoA) for %BF.

Results

Four BIA devices demonstrated moderate reliability (ICC: 0.66-0.73) and two devices demonstrated poor reliability (ICC: 0.25 and 0.43). The most favorable agreement profile from a BIA device was a mean bias of -2.21% and relatively narrow LoA (-9.88% - 5.46%). The least favorable agreement profile from a BIA device was a mean bias of 2.88% and LoA of –10.25% –16.01%.

Conclusions

The present study indicated that multi-frequency BIA devices outperformed single-frequency BIA devices, and that the Omron had the highest LoA with DXA.

Zitieren

APA

Irwin, G., Cruz, A. A. B., Chandler, A., Brush, C., & Brown, A. F. (2025). Agreement Between Six Bioelectrical Impedance Analysis Devices and Dual-Energy X-Ray Absorptiometry. Journal of Exercise and Nutrition, 8(1). https://doi.org/10.53520/jen2025.103206

Vancouver

Irwin G, Cruz AAB, Chandler A, Brush C, Brown AF. Agreement Between Six Bioelectrical Impedance Analysis Devices and Dual-Energy X-Ray Absorptiometry. Journal of Exercise and Nutrition. 2025;8(1). doi:10.53520/jen2025.103206

BibTeX
@article{Irwin2025,
  author = {Irwin, Gena and Cruz, Ariel Aguiar Bonfim and Chandler, Alexa and Brush, C.J. and Brown, Ann Frost},
  title = {Agreement Between Six Bioelectrical Impedance Analysis Devices and Dual-Energy X-Ray Absorptiometry},
  journal = {Journal of Exercise and Nutrition},
  year = {2025},
  volume = {8},
  number = {1},
  doi = {10.53520/jen2025.103206}
}
Kostenlos starten →