Fat and fat‐free mass measurement agreement by dual‐energy X‐ray absorptiometry versus bioelectrical impedance analysis: Effects of posture and waist circumference
Obesity Science & Practice · 2024-04 · 10 (2)
DOI: 10.1002/osp4.744 ↗Kurz gefasst
Fachartikel in der Zeitschrift Obesity Science & Practice, online erschienen am 11.03.2024. Verfasst von Katie M Ellison und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nutrition Sciences The University of Alabama at Birmingham Birmingham Alabama USA. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIDDK NIH HHS.
Abstract (Originalsprache)
Background
Bioelectrical impedance analysis (BIA) operates under the assumption that the conductor has a uniform cylindrical shape. However, this assumption may be violated if measures are taken in the seated position, especially in people with a high waist circumference (WC).
Aims
The aims of this research were to determine whether posture (supine, standing, and seated) and WC affect agreement between BIA and dual‐energy X‐ray absorptiometry (DXA) measures of fat mass (FM) and fat‐free mass (FFM). Materials & Methods Baseline data were collected from 28 adults (mean = 61.4 ± 6.9 years, 64.3% female) with obesity (BMI 38.6 ± 5.0 kg/m 2 ). Body composition was measured using BIA in the supine, standing, and seated positions and by DXA while supine. Intraclass correlation coefficient (ICC) analyses with two‐way mixed effects and absolute agreement were performed to determine agreement.
Results
Point estimates were excellent for FM and FFM while supine, excellent for FM and good for FFM while standing, and moderate for FM and good for FFM while seated. BIA measures in the supine position resulted in the narrowest 95% confidence intervals compared with other positions. Better agreement was observed across all positions in participants with a WC below the median (118.3 cm).
Discussion
Despite the potential pragmatic value of measuring with BIA in a seated position, the results of this analysis demonstrate the poorest agreement between DXA and BIA methods, especially in individuals with high WC.
Conclusion
Findings from this study demonstrate that BIA, particularly when measured in a supine position, can serve as a viable alternative to DXA for measuring body composition in people with obesity.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nutrition Sciences The University of Alabama at Birmingham Birmingham Alabama USA.
- Department of Family and Community Medicine The University of Alabama at Birmingham Birmingham Alabama USA.
ORCID-Profile: Katie M Ellison, R Drew Sayer
Förderung
- NIDDK NIH HHS
Zitieren
APA
Ellison, K. M., Ehrlicher, S. E., El Zein, A., & Sayer, R. D. (2024). Fat and fat‐free mass measurement agreement by dual‐energy X‐ray absorptiometry versus bioelectrical impedance analysis: Effects of posture and waist circumference. Obesity Science & Practice, 10(2). https://doi.org/10.1002/osp4.744
Vancouver
Ellison KM, Ehrlicher SE, El Zein A, Sayer RD. Fat and fat‐free mass measurement agreement by dual‐energy X‐ray absorptiometry versus bioelectrical impedance analysis: Effects of posture and waist circumference. Obesity Science & Practice. 2024;10(2). doi:10.1002/osp4.744
BibTeX
@article{Ellison2024,
author = {Ellison, Katie M and Ehrlicher, Sarah E and El Zein, Aseel and Sayer, R Drew},
title = {Fat and fat‐free mass measurement agreement by dual‐energy X‐ray absorptiometry versus bioelectrical impedance analysis: Effects of posture and waist circumference},
journal = {Obesity Science & Practice},
year = {2024},
volume = {10},
number = {2},
doi = {10.1002/osp4.744}
}
EUVIMED