EUVIMEDEUVIMED entdecken
Systematische ÜbersichtMetaanalyse

Trimester‐specific diagnostic accuracy of ultrasound for detection of placenta accreta spectrum: systematic review and meta‐analysis

K Hessami iD, R Horgan iD, J L Munoz, A H Norooznezhad iD, A A Nassr iD, K A Fox iD, D Di Mascio iD, M Caldwell, V Catania iD, F D'Antonio iD, A Z Abuhamad

Ultrasound in Obstetrics & Gynecology · 2024-06 · 63 (6) · 723-730

DOI: 10.1002/uog.27606 ↗

Kurz gefasst

Systematische Übersicht in der Zeitschrift Ultrasound in Obstetrics & Gynecology, online erschienen am 02.06.2024. Verfasst von K Hessami und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA. Hauptthemen laut MEDLINE: Placenta Accreta, Ultrasonography, Prenatal, Sensitivity and Specificity, Pregnancy Trimester, First. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 56 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the diagnostic accuracy of ultrasound for detecting placenta accreta spectrum (PAS) during the first trimester of pregnancy and compare it with the accuracy of second‐ and third‐trimester ultrasound examination in pregnancies at risk for PAS.

Methods

PubMed, EMBASE and Web of Science databases were searched to identify relevant studies published from inception until 10 March 2023. Inclusion criteria were cohort, case–control or cross‐sectional studies that evaluated the accuracy of ultrasound examination performed at < 14 weeks of gestation (first trimester) or ≥ 14 weeks of gestation (second/third trimester) for the diagnosis of PAS in pregnancies with clinical risk factors. The primary outcome was the diagnostic accuracy of sonography in detecting PAS in the first trimester, compared with the accuracy of ultrasound examination in the second and third trimesters. The secondary outcome was the diagnostic accuracy of each sonographic marker individually across the trimesters of pregnancy. The reference standard was PAS confirmed at pathological or surgical examination. The potential of ultrasound and different ultrasound signs to detect PAS was assessed by computing summary estimates of sensitivity, specificity, diagnostic odds ratio and positive and negative likelihood ratios.

Results

A total of 37 studies, including 5764 pregnancies at risk of PAS, with 1348 cases of confirmed PAS, were included in our analysis. The meta‐analysis demonstrated that ultrasound had a sensitivity of 86% (95% CI, 78–92%) and specificity of 63% (95% CI, 55–70%) during the first trimester, and a sensitivity of 88% (95% CI, 84–91%) and specificity of 92% (95% CI, 85–96%) during the second/third trimester. Regarding sonographic markers examined in the first trimester, lower uterine hypervascularity exhibited the highest sensitivity (97% (95% CI, 19–100%)), and uterovesical interface irregularity demonstrated the highest specificity (99% (95% CI, 96–100%)). In the second/third trimester, loss of clear zone had the highest sensitivity (80% (95% CI, 72–86%)), and uterovesical interface irregularity exhibited the highest specificity (99% (95% CI, 97–100%)).

Conclusions

First‐trimester ultrasound examination has similar accuracy to second‐ and third‐trimester ultrasound examinations for the diagnosis of PAS. Routine first‐trimester ultrasound screening for patients at high risk of PAS may improve detection rates and allow earlier referral to tertiary care centers for pregnancy management. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Placenta AccretaUltrasonography, PrenatalSensitivity and SpecificityPregnancy Trimester, FirstHumansFemalePregnancyPregnancy Trimester, ThirdPregnancy Trimester, SecondPregnancy Trimesters

Stichwörter der Autor:innen

first trimesterinvasive placentamorbidly adherent placentaplacenta accretasecond trimestersonographythird trimesterultrasound

Autor:innen und Institutionen

  • Department of Obstetrics and Gynecology, Baylor College of Medicine, Houston, TX, USA.
  • Department of Obstetrics and Gynecology, Eastern Virginia Medical School, Norfolk, VA, USA.
  • Division of Fetal Therapy and Surgery, Baylor College of Medicine, Houston, TX, USA.
  • Medical Biology Research Centre, Health Technology Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran.
  • Department of Obstetrics and Gynecology, The University of Texas Medical Branch at Galveston, Galveston, TX, USA.
  • Department of Maternal and Child Health and Urological Sciences, Sapienza University of Rome, Rome, Italy.

ORCID-Profile: K Hessami, R Horgan, A H Norooznezhad, A A Nassr, K A Fox, D Di Mascio, V Catania, F D'Antonio

Zitieren

APA

Hessami, K., Horgan, R., Munoz, J. L., Norooznezhad, A. H., Nassr, A. A., Fox, K. A., Di Mascio, D., Caldwell, M., Catania, V., D'Antonio, F., & Abuhamad, A. Z. (2024). Trimester‐specific diagnostic accuracy of ultrasound for detection of placenta accreta spectrum: systematic review and meta‐analysis. Ultrasound in Obstetrics & Gynecology, 63(6), 723-730. https://doi.org/10.1002/uog.27606

Vancouver

Hessami K, Horgan R, Munoz JL, Norooznezhad AH, Nassr AA, Fox KA, et al. Trimester‐specific diagnostic accuracy of ultrasound for detection of placenta accreta spectrum: systematic review and meta‐analysis. Ultrasound in Obstetrics & Gynecology. 2024;63(6):723-730. doi:10.1002/uog.27606

BibTeX
@article{Hessami2024,
  author = {Hessami, K and Horgan, R and Munoz, J L and Norooznezhad, A H and Nassr, A A and Fox, K A and Di Mascio, D and Caldwell, M and Catania, V and D'Antonio, F and Abuhamad, A Z},
  title = {Trimester‐specific diagnostic accuracy of ultrasound for detection of placenta accreta spectrum: systematic review and meta‐analysis},
  journal = {Ultrasound in Obstetrics & Gynecology},
  year = {2024},
  volume = {63},
  number = {6},
  pages = {723--730},
  doi = {10.1002/uog.27606}
}
Kostenlos starten →