EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Increase in pulp chamber temperature during irradiation with high-power diode laser: an in vitro study

Luciana Roggia Friedrich, Brenda Hammes do Nascimento, Marcela Marquezan, Rachel De Oliveira Rocha, Dra Mariana Marquezan, Bruno Lopes da Silveira

Revista da Faculdade de Odontologia - UPF · 18.12.2025 · 30 (1)

DOI: 10.5335/rfo.v30i1.17558 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista da Faculdade de Odontologia - UPF, online erschienen am 18.12.2025. Verfasst von Luciana Roggia Friedrich und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this in vitro study was to evaluate the variation in pulp chamber temperature during diode laser irradiation using different power and time parameters.

Methods

Ten human mandibular central incisors (n=10) were selected, and their root canals were enlarged and filled with thermal paste. The root portion remained submerged in a thermal bath at 37°C, and a thermocouple sensor connected to a digital thermometer was placed inside the pulp chamber to measure the temperature variation. The diode laser (810 nm) was applied at a distance of 1 cm from the dental surface, using power settings of 1, 2, and 3 W in continuous mode, for 5, 10, 15, 20, and 25 seconds. For each power setting and for each tooth, five temperature measurements were taken in addition to the baseline measurement. Data were analyzed using analysis of variance (ANOVA) and Tukey’s post-hoc test (α = 5%).

Results

A statistically significant difference was observed between all temperature readings compared to the baseline, as well as among all time intervals, indicating a progressive temperature increase over time for all three tested power settings. Furthermore, higher power resulted in greater temperature elevation (P ≤ 0.05).

Conclusion

The irradiation parameters used in this study led to a progressive increase in pulp chamber temperature, without exceeding the 5.5 °C threshold associated with irreversible pulpal damage.

Zitieren

APA

Friedrich, L. R., Nascimento, B. H. D., Marquezan, M., Rocha, R. D. O., Marquezan, D. M., & Silveira, B. L. D. (2025). Increase in pulp chamber temperature during irradiation with high-power diode laser: an in vitro study. Revista da Faculdade de Odontologia - UPF, 30(1). https://doi.org/10.5335/rfo.v30i1.17558

Vancouver

Friedrich LR, Nascimento BHD, Marquezan M, Rocha RDO, Marquezan DM, Silveira BLD. Increase in pulp chamber temperature during irradiation with high-power diode laser: an in vitro study. Revista da Faculdade de Odontologia - UPF. 2025;30(1). doi:10.5335/rfo.v30i1.17558

BibTeX
@article{Friedrich2025,
  author = {Friedrich, Luciana Roggia and Nascimento, Brenda Hammes do and Marquezan, Marcela and Rocha, Rachel De Oliveira and Marquezan, Dra Mariana and Silveira, Bruno Lopes da},
  title = {Increase in pulp chamber temperature during irradiation with high-power diode laser: an in vitro study},
  journal = {Revista da Faculdade de Odontologia - UPF},
  year = {2025},
  volume = {30},
  number = {1},
  doi = {10.5335/rfo.v30i1.17558}
}
Kostenlos starten →