Fascia‐Level Temperature Kinetics During Multi‐Wavelength Diode Laser Irradiation: A Cadaveric Study
Journal of Cosmetic Dermatology · 2026-05 · 25 (5)
DOI: 10.1111/jocd.70905 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cosmetic Dermatology, online erschienen am 16.05.2026. Verfasst von Kyu-Ho Yi und 4 weiteren Autor:innen. Beteiligte Einrichtung: You and I Clinic, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Lasers, Semiconductor, Fascia, Body Temperature. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Thermal energy‐based technologies are widely used for noninvasive body contouring; however, quantitative characterization of fascia‐level heat propagation in body tissues during multi‐wavelength diode laser irradiation remains limited.
Objective
To assess fascia‐level temperature kinetics and regional differences in deep‐plane heating during stacking delivery of a multi‐wavelength diode laser (Fortra, Classys Inc., Korea) in human cadaver tissues.
Methods
Three fresh‐frozen human cadavers underwent laser irradiation at the abdomen, anterior thigh, and lateral upper arm. Subcutaneous fat thickness was measured by ultrasonography. A single thermocouple was inserted to the muscle fascial plane to record fascia‐level temperature over time, and infrared thermography of the exposed measurement field was performed after tissue exposure to identify the local thermographic peak. Deep fascial arrival time, peak fascial temperature, exposed‐field thermographic peak temperature, and fascia‐level cumulative equivalent minutes at 43°C (CEM43) were evaluated. Regional comparisons were descriptive, with exploratory nonparametric testing.
Results
Heat reached the muscle fascia fastest in the anterior thigh (4.9 ± 0.4 s), followed by the lateral upper arm (5.3 ± 0.5 s), and slowest in the abdomen (6.6 ± 0.6 s). These values represent mean ± SD of cadaver‐level means. Regional differences in fascial arrival time were exploratory but reached significance (Friedman test, p = 0.049). Exposed‐field thermographic peak temperatures were highest in the anterior thigh (70°C–72°C), followed by the lateral upper arm (68°C–71°C), and lowest in the abdomen (65°C–68°C).
Conclusions
Under non‐perfused ex vivo conditions, fascia‐level thermal behavior during multi‐wavelength diode laser irradiation varied by anatomical region. Greater subcutaneous fat thickness was associated with slower fascial heat arrival, but did not fully explain regional variation. These findings are descriptive and do not establish volumetric heat distribution, histologic injury, or in vivo safety thresholds.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- You and I Clinic, Seoul, Republic of Korea.
- Medical Research, Seoul, Republic of Korea.
- Centre Médical Saint Jean, Arras, France.
- Cabinet Médical, Senlis, France.
- SIBUS, Paris, France.
ORCID-Profile: Kyu-Ho Yi
Zitieren
APA
Yi, K. H., Park, Y., Cartier, H., Garson, S., & Ascher, B. (2026). Fascia‐Level Temperature Kinetics During Multi‐Wavelength Diode Laser Irradiation: A Cadaveric Study. Journal of Cosmetic Dermatology, 25(5). https://doi.org/10.1111/jocd.70905
Vancouver
Yi KH, Park Y, Cartier H, Garson S, Ascher B. Fascia‐Level Temperature Kinetics During Multi‐Wavelength Diode Laser Irradiation: A Cadaveric Study. Journal of Cosmetic Dermatology. 2026;25(5). doi:10.1111/jocd.70905
BibTeX
@article{Yi2026,
author = {Yi, Kyu-Ho and Park, Yerin and Cartier, Hugues and Garson, Sebastien and Ascher, Benjamin},
title = {Fascia‐Level Temperature Kinetics During Multi‐Wavelength Diode Laser Irradiation: A Cadaveric Study},
journal = {Journal of Cosmetic Dermatology},
year = {2026},
volume = {25},
number = {5},
doi = {10.1111/jocd.70905}
}
EUVIMED