"Impact of Experimental Measurements Accuracy on Validation Process of Crimped Connections"

Alin-Iulian Dolan, Constantin-Florin Ocoleanu

Annals of the University of Craiova, Electrical Engineering Series · 2022

DOI: 10.52846/aucee.2021.1.03 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of the University of Craiova, Electrical Engineering Series, 2022. Verfasst von Alin-Iulian Dolan und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

"In the process of validation of crimped connections, the determination of the connector resistance factor and of the initial scatter coefficient has a decisive role. In this paper is studied the impact of the experimental measurements accuracy on the calculation of initial scatter, cumulating data from various types of crimped connections. This coefficient provides information on the behavior of the crimped connection immediately after installation before any aging effect begins. The standards establish that 6 samples are sufficient to be tested to estimate the identification of a “family” of connectors. The measurements were performed on crimped connections of barrel of terminal lug type for three cross sections of cables and on crimped connections of bimetallic through connector type for two pairs of cross sections. The initial scatter is influenced by 6 representative measured quantities as voltage drops, currents and conductor lengths. First, it was imposed a variation by one unit of hundredths digit of initial scatter and was recorded the variation of each quantity, the others 5 quantities being kept constant. Then simultaneous variations of the 6 quantities caused by device reading errors were imposed, determining the quantities with the greatest influence on initial scatter. Useful recommendations for experimenter are made. "

Zitieren

APA

Dolan, A., & Ocoleanu, C. (2022). "Impact of Experimental Measurements Accuracy on Validation Process of Crimped Connections". Annals of the University of Craiova, Electrical Engineering Series. https://doi.org/10.52846/aucee.2021.1.03

Vancouver

Dolan A, Ocoleanu C. "Impact of Experimental Measurements Accuracy on Validation Process of Crimped Connections". Annals of the University of Craiova, Electrical Engineering Series. 2022. doi:10.52846/aucee.2021.1.03

BibTeX
@article{Dolan2022,
  author = {Dolan, Alin-Iulian and Ocoleanu, Constantin-Florin},
  title = {"Impact of Experimental Measurements Accuracy on Validation Process of Crimped Connections"},
  journal = {Annals of the University of Craiova, Electrical Engineering Series},
  year = {2022},
  doi = {10.52846/aucee.2021.1.03}
}
Kostenlos starten →