Impact of the β correction factor on the accuracy of speckle contrast imaging measurements
Biomedical Optics Express · 01.05.2026 · 17 (5) · 2298
DOI: 10.1364/boe.588672 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Optics Express, online erschienen am 10.04.2026. Verfasst von Nataliya Makeeva und 3 weiteren Autor:innen. Beteiligte Einrichtung: University of California, Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, USA. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: U.S. Army Institute of Surgical Research, Air Force Office of Scientific Research, Arnold and Mabel Beckman Foundation.
Abstract (Originalsprache)
Laser speckle imaging (LSI) is a non-invasive technique for quantifying superficial blood flow based on speckle contrast analysis. A critical factor influencing blood flow calculations is the β coefficient, which accounts for system-specific parameters such as speckle-to-pixel size ratio and light polarization. While β is often assumed based on the system’s settings, this simplification introduces variability and error in flow quantification, limiting reproducibility and cross-system comparisons. In this study, we present a β-correction approach that uses static phantom measurements to empirically determine β and apply it to correct speckle flow index (SFI) values. We validate this method across three experimental conditions (varying detector polarization, speckle-to-pixel size ratios, and different LSI systems) using both in vitro and in vivo data. Our results demonstrate that β-correction significantly reduces intra-system and day-to-day measurement variability and partially improves inter-system consistency, particularly at low flow speeds. This method enhances LSI reliability for longitudinal clinical monitoring within individual systems by reducing day-to-day measurement variability. While β-correction provides partial improvement with lower coefficients of variation for inter-system consistency at low flow speeds, its primary value lies in standardizing repeated measurements over time.
Autor:innen und Institutionen
- University of California, Irvine, Beckman Laser Institute and Medical Clinic, Irvine, California, USA.
- University of California, Irvine, Department of Biomedical Engineering, Irvine, California, USA.
- University of California, Irvine, Department of Surgery, Irvine, California, USA.
ORCID-Profile: Christian Crouzet, Bernard Choi
Förderung
- U.S. Army Institute of Surgical Research
- Air Force Office of Scientific Research
- Arnold and Mabel Beckman Foundation
Zitieren
APA
Makeeva, N., Ong, M., Crouzet, C., & Choi, B. (2026). Impact of the β correction factor on the accuracy of speckle contrast imaging measurements. Biomedical Optics Express, 17(5), 2298. https://doi.org/10.1364/boe.588672
Vancouver
Makeeva N, Ong M, Crouzet C, Choi B. Impact of the β correction factor on the accuracy of speckle contrast imaging measurements. Biomedical Optics Express. 2026;17(5):2298. doi:10.1364/boe.588672
BibTeX
@article{Makeeva2026,
author = {Makeeva, Nataliya and Ong, Markus and Crouzet, Christian and Choi, Bernard},
title = {Impact of the β correction factor on the accuracy of speckle contrast imaging measurements},
journal = {Biomedical Optics Express},
year = {2026},
volume = {17},
number = {5},
pages = {2298},
doi = {10.1364/boe.588672}
}