EUVIMEDSkopri EUVIMED
Crossref

A Low-Cost, Reusable Cricothyroidotomy Simulator for Resource-Limited Settings: Design and Initial Teaching Use

Ojasvi Sharma, Thomas Khairy, Ryan Kara, Arjun Gupta, Dan Deckelbaum, Jeremy Grushka

Journal Of Global Surgery (ONE) · 2026-11-12 · 2 (2) · 185-193

DOI: 10.52648/jogs.1326 ↗

At a glance

Journal article in Journal Of Global Surgery (ONE), published online on 2026-11-03. Written by Ojasvi Sharma and 5 co-authors. 22 references.

AstrattDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Purpose

Cricothyroidotomy is a lifesaving emergency procedure for managing airway obstruction. However, training opportunities in low- and middle-income countries (LMICs) are limited by the high cost and complexity of existing simulation models. Recognizing this gap, we developed a low-cost, reusable cricothyroidotomy simulator intended for surgical skills training in LMICs.

Methods

The simulator is built from medical gloves, bandage, corrugated cardboard and duct tape, following an illustrated 13-step guide. It represents the skin, soft tissue, thyroid and cricoid cartilages, and cricothyroid membrane, and weighs under 2 lb (0.9 kg). After each attempt, the glove, bandage and membrane tape are replaced and the cardboard framework is reused. Material costs were prorated from retail prices. Three trauma surgeons examined the model informally during conference judging, and it was then used in teaching sessions with trainees.

Results

Buying one package of each material cost US$19.12. The materials consumed in building one simulator cost US$1.84, and the replacement layers for each further attempt cost US$0.85. Furthermore, assembly took under five minutes and replacing the consumable layers about one minute. The surgeons commented that the landmarks were identifiable by palpation and that the procedural sequence could be completed on the model. During teaching, learners incised the skin and membrane, confirmed airway entry digitally and inserted a tube, and the cardboard framework remained intact across repeated attempts.

Conclusion

This low-cost, reusable cricothyroidotomy simulator represents an early-phase training innovation intended to improve access to repeated hands-on practice in resource-limited settings. Structured evaluation and field testing in LMICs are planned.

Cite

APA

Sharma, O., Khairy, T., Kara, R., Gupta, A., Deckelbaum, D., & Grushka, J. (2026). A Low-Cost, Reusable Cricothyroidotomy Simulator for Resource-Limited Settings: Design and Initial Teaching Use. Journal Of Global Surgery (ONE), 2(2), 185-193. https://doi.org/10.52648/jogs.1326

Vancouver

Sharma O, Khairy T, Kara R, Gupta A, Deckelbaum D, Grushka J. A Low-Cost, Reusable Cricothyroidotomy Simulator for Resource-Limited Settings: Design and Initial Teaching Use. Journal Of Global Surgery (ONE). 2026;2(2):185-193. doi:10.52648/jogs.1326

BibTeX
@article{Sharma2026,
  author = {Sharma, Ojasvi and Khairy, Thomas and Kara, Ryan and Gupta, Arjun and Deckelbaum, Dan and Grushka, Jeremy},
  title = {A Low-Cost, Reusable Cricothyroidotomy Simulator for Resource-Limited Settings: Design and Initial Teaching Use},
  journal = {Journal Of Global Surgery (ONE)},
  year = {2026},
  volume = {2},
  number = {2},
  pages = {185--193},
  doi = {10.52648/jogs.1326}
}
Start for free →