EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Surgeon Proficiency Determines Tibiofemoral Contact Pressures, Dynamic Ligament Laxity, And Polyethylene Wear Risk In Navigation-Assisted Total Knee Arthroplasty: A Finite Element

Helder Rocha da Silva Araújo, Andrei Machado Viegas da Trindade, Davi de Souza Garcia, Enio Chaves de Oliveira, Fernanda Grazielle da Silva Azevedo Nora

The Journal of Orthopaedics · 06.05.2026 · 17 (1)

DOI: 10.52338/tjop.2026.5560 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Orthopaedics, online erschienen am 06.05.2026. Verfasst von Helder Rocha da Silva Araújo und 4 weiteren Autor:innen. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To quantify the influence of surgeon experience on dynamic tibiofemoral contact mechanics and gait kinematics after navigation- assisted total knee arthroplasty (TKA) using a finite element–inspired gait simulation framework.

Methods

A retrospective observational study was conducted using prospectively collected intraoperative navigation datasets from primary unilateral TKA performed with the SCORE® mobile-bearing prosthesis and Amplivision® optical navigation system (Amplitude Surgical, Valence, France). Surgeons were stratified into E1 (beginner; ≤15 procedures; 32 surgeons, 279 cases) and E2 (experienced; >21 procedures; 11 surgeons, 349 cases). A reduced-order finite element–inspired proxy model implemented in Python simulated continuous gait (0–100%) to estimate femoral and tibial contact pressures, polyethylene inserts contact stress (10–20 mm), knee range of motion, dynamic ligament balance (GAP), and coronal-plane angles. Intergroup comparisons used the Mann–Whitney U test; effect sizes (Cohen’s d and Cliff’s δ) with 95% bootstrap confidence intervals (2,000 iterations) were computed.

Results

Across all contact mechanics outcomes, E1 reconstructions demonstrated higher loading than E2, including mean femoral contact pressure (26.74 ± 21.59 vs 22.44 ± 17.34 MPa; p = 0.083) and mean tibial contact pressure (26.21 ± 21.16 vs 21.99 ± 17.00 MPa; p = 0.079). Peak pressures followed the same pattern (femoral: 0.44 ± 0.36 vs 0.37 ± 0.29 MPa; tibial: 0.43 ± 0.35 vs 0.36 ± 0.28 MPa; p = 0.083). Polyethylene insert stress decreased with increasing thickness (10→20 mm) in both cohorts yet remained consistently higher in E1. Kinematic variables were also greater in E1, including range of motion (74.1 ± 3.8 vs 72.9 ± 3.5°; p = 0.088), mean GAP (2.21 ± 0.90 vs 0.67 ± 0.32 mm; p = 0.081), mean varus angle (1.12 ± 0.46 vs 0.98 ± 0.39°; p = 0.087), and mean valgus angle (2.01 ± 0.62 vs 1.82 ± 0.55°; p = 0.090). Effect sizes were uniformly small-to-mod

Zitieren

APA

Araújo, H. R. D. S., Trindade, A. M. V. D., Garcia, D. D. S., Oliveira, E. C. D., & Nora, F. G. D. S. A. (2026). Surgeon Proficiency Determines Tibiofemoral Contact Pressures, Dynamic Ligament Laxity, And Polyethylene Wear Risk In Navigation-Assisted Total Knee Arthroplasty: A Finite Element. The Journal of Orthopaedics, 17(1). https://doi.org/10.52338/tjop.2026.5560

Vancouver

Araújo HRDS, Trindade AMVD, Garcia DDS, Oliveira ECD, Nora FGDSA. Surgeon Proficiency Determines Tibiofemoral Contact Pressures, Dynamic Ligament Laxity, And Polyethylene Wear Risk In Navigation-Assisted Total Knee Arthroplasty: A Finite Element. The Journal of Orthopaedics. 2026;17(1). doi:10.52338/tjop.2026.5560

BibTeX
@article{Arajo2026,
  author = {Araújo, Helder Rocha da Silva and Trindade, Andrei Machado Viegas da and Garcia, Davi de Souza and Oliveira, Enio Chaves de and Nora, Fernanda Grazielle da Silva Azevedo},
  title = {Surgeon Proficiency Determines Tibiofemoral Contact Pressures, Dynamic Ligament Laxity, And Polyethylene Wear Risk In Navigation-Assisted Total Knee Arthroplasty: A Finite Element},
  journal = {The Journal of Orthopaedics},
  year = {2026},
  volume = {17},
  number = {1},
  doi = {10.52338/tjop.2026.5560}
}
Kostenlos starten →