Vergleichsstudie

Assessment of joint laxity following total knee arthroplasty: A comparison of tensioner device, navigation, and robot evaluation

Hiroshi Inui, Haruhiko Nakamura, Ryota Takei, Masaki Uchida, Kei Satou, Tetsu Yamashita, Risa Matsumoto, Kazuo Saita

The Knee · 2025-10 · 56 · 397-406

DOI: 10.1016/j.knee.2025.06.020 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift The Knee, 2025-10. Verfasst von Hiroshi Inui und 7 weiteren Autor:innen. Beteiligte Einrichtung: Saitama Medical Center, Saitama Medical University, Japan. Electronic address: hiroshi_inu0707@yahoo.co.jp. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Joint Instability, Robotic Surgical Procedures, Knee Joint. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 26 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Appropriate soft-tissue balance is essential for total knee arthroplasty (TKA). Widely used techniques to evaluate soft-tissue balance are measuring the joint gap using tensioner devices, the robot and the navigation. We compared soft-tissue balance evaluated using tensioner, navigation, and robot tools. METHODS: 81 patients who underwent bi-cruciate stabilized (BCS) TKA were included. 41 patients were performed using the navigation (Group N) and 40 patients were performed using the robot (Group R). After the final implantation, the joint laxities were measured using tensioner device (JLT) and navigation (JLN) in group N and measured using tensioner device and robot (JLR) in group R. The evaluations were performed at a flexion of 10°, 30°, 60° and 90°. Joint laxities evaluated by the different tools were compared in both groups. RESULTS: No significant between-group differences were observed for JLTs at each flexion angle in both compartments. The JLTs of were larger than JLNs at 90°. The JLTs were larger than JLRs at 30°, 60°and 90°. At a knee flexion angle of 60°, the difference between JLTs and JLRs were larger than that between JLTs and JLNs. The JLTs were smaller than JLNs at 60°and 90°in the lateral compartment. CONCLUSION: Joint laxities evaluated using the tensioner device with a distraction force of 80 N for both compartments were similar to those evaluated with the robot and the navigation in extension position. However joint laxities evaluated using the tensioner device were larger than those evaluated with robot and the navigation in flexion position.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeJoint InstabilityRobotic Surgical ProceduresKnee JointOsteoarthritis, KneeRoboticsHumansFemaleMaleAgedMiddle AgedRange of Motion, ArticularSurgery, Computer-AssistedAged, 80 and over

Stichwörter der Autor:innen

Joint laxityNavigationRobotTensioner device

Autor:innen und Institutionen

  • Saitama Medical Center, Saitama Medical University, Japan. Electronic address: hiroshi_inu0707@yahoo.co.jp.
  • Saitama Medical Center, Saitama Medical University, Japan.
  • Saitama Medical Center, Saitama Medical University, Japan. Electronic address: m05071@msn.com.
  • Saitama Medical Center, Saitama Medical University, Japan. Electronic address: saita@saitama-med.ac.jp.

Zitieren

APA

Inui, H., Nakamura, H., Takei, R., Uchida, M., Satou, K., Yamashita, T., Matsumoto, R., & Saita, K. (2025). Assessment of joint laxity following total knee arthroplasty: A comparison of tensioner device, navigation, and robot evaluation. The Knee, 56, 397-406. https://doi.org/10.1016/j.knee.2025.06.020

Vancouver

Inui H, Nakamura H, Takei R, Uchida M, Satou K, Yamashita T, et al. Assessment of joint laxity following total knee arthroplasty: A comparison of tensioner device, navigation, and robot evaluation. The Knee. 2025;56:397-406. doi:10.1016/j.knee.2025.06.020

BibTeX
@article{Inui2025,
  author = {Inui, Hiroshi and Nakamura, Haruhiko and Takei, Ryota and Uchida, Masaki and Satou, Kei and Yamashita, Tetsu and Matsumoto, Risa and Saita, Kazuo},
  title = {Assessment of joint laxity following total knee arthroplasty: A comparison of tensioner device, navigation, and robot evaluation},
  journal = {The Knee},
  year = {2025},
  volume = {56},
  pages = {397--406},
  doi = {10.1016/j.knee.2025.06.020}
}
Kostenlos starten →