EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Radiographic acetabulotrochanteric distance measurement as a novel method for determining leg length discrepancy in patients with hemiarthroplasty

Ugur Yuzuguldu, Bilge Kagan Yilmaz, Ibrahim Ethem Butuner, Murat Yesil, Gokhan Maralcan

Joint Diseases and Related Surgery · 2025

DOI: 10.52312/jdrs.2025.2285 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Joint Diseases and Related Surgery, 2025. Verfasst von Ugur Yuzuguldu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Atatürk Şehir Hastanesi, Ortopedi ve Travmatoloji Kliniği, 10100 Altıeylül, Balıkesir, Türkiye. uguryuzuguldu@gmail.com. Hauptthemen laut MEDLINE: Leg Length Inequality, Hemiarthroplasty, Femur, Acetabulum. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: This study aims to evaluate the interobserver reliability and interobserver reproducibility of radiographic acetabulotrochanteric distance (ATD) measurement and to investigate its accuracy by comparing it with conventional radiographic methods used in leg length discrepancy (LLD) measurement. PATIENTS AND METHODS: Between January 2017 and January 2022, a total of 97 patients (39 males, 58 females; mean age: 77.8±7.1 years; range, 61 to 91 years) who underwent pelvic radiographic evaluation and hemiarthroplasty (HA) due to femoral neck fracture were retrospectively analyzed. For ATD measurement, the distance between the line connecting the upper cartilage of the acetabulum (AC) and the extreme point of the greater trochanter (GT) was used. The AC-GT measurement on both sides was compared with bottom of the ischial tuberosities-lesser trochanter (BI-LT), center of the femoral head-BI (CH-BI), inferior acetabular teardrops-LT (IT-LT) measurements. The agreement between the methods was examined with the intraclass correlation coefficient (CCI). RESULTS: According to the AC-GT & BI-LT, AC-GT & BI-CH methods, there were very strong (ICC: 0.75), moderate (ICC: 0.69) and acceptable (ICC: 0.33) agreements, respectively. Significant agreement was found between all measurements (p 0.8). CONCLUSION: The ATD measurement correlates well with known measurement techniques on pelvic radiography and can be used as an alternative to this method. It has excellent intra- and interobserver agreements. This method can predict LLD after HA, but does not consider other length differences in the lower limbs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Leg Length InequalityHemiarthroplastyFemurAcetabulumFemoral Neck FracturesRadiographyHumansMaleFemaleAgedAged, 80 and overRetrospective StudiesMiddle AgedReproducibility of ResultsObserver Variation

Autor:innen und Institutionen

  • Atatürk Şehir Hastanesi, Ortopedi ve Travmatoloji Kliniği, 10100 Altıeylül, Balıkesir, Türkiye. uguryuzuguldu@gmail.com.

Zitieren

APA

Yuzuguldu, U., Yilmaz, B. K., Butuner, I. E., Yesil, M., & Maralcan, G. (2025). Radiographic acetabulotrochanteric distance measurement as a novel method for determining leg length discrepancy in patients with hemiarthroplasty. Joint Diseases and Related Surgery. https://doi.org/10.52312/jdrs.2025.2285

Vancouver

Yuzuguldu U, Yilmaz BK, Butuner IE, Yesil M, Maralcan G. Radiographic acetabulotrochanteric distance measurement as a novel method for determining leg length discrepancy in patients with hemiarthroplasty. Joint Diseases and Related Surgery. 2025. doi:10.52312/jdrs.2025.2285

BibTeX
@article{Yuzuguldu2025,
  author = {Yuzuguldu, Ugur and Yilmaz, Bilge Kagan and Butuner, Ibrahim Ethem and Yesil, Murat and Maralcan, Gokhan},
  title = {Radiographic acetabulotrochanteric distance measurement as a novel method for determining leg length discrepancy in patients with hemiarthroplasty},
  journal = {Joint Diseases and Related Surgery},
  year = {2025},
  doi = {10.52312/jdrs.2025.2285}
}
Kostenlos starten →