A comparison between 3D printed models and standard 2D planning in the use of metal block augments in revision knee arthroplasty
Joint Diseases and Related Surgery · 2024
DOI: 10.52312/jdrs.2024.1591 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Joint Diseases and Related Surgery, 2024. Verfasst von Giovanni Balato und 8 weiteren Autor:innen. Beteiligte Einrichtung: Unit of Orthopaedic Surgery, Department of Public Health, School of Medicine, Federico II University, Naples, Italy. vincenzo.dematteo@unina.it. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Printing, Three-Dimensional, Reoperation, Knee Prosthesis. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVES: The study focused on the ability to predict the need and size of femoral and tibial augmentation using standard two-dimensional (2D) templates and models created with three-dimensional (3D) printing in surgical planning. PATIENTS AND METHODS: This observational cohort study included 28 consecutive patients (22 females, 6 males; mean age: 71±7.3 years; range, 54 to 82 years) with periprosthetic joint infection recruited between March 2021 and September 2023 undergoing revision total knee arthroplasty revision (TKA). Standard planning was made using calibrated X-ray images. The 3D planning started with computed tomography scans to generate a 3D template of the distal femur and proximal tibia. The model was exported to a 3D printer to produce a patient-specific phantom. The surgery was then simulated on the 3D phantom using revision knee arthroplasty instrumentation to evaluate the appropriate augmentation to use until a correct alignment was obtained. RESULTS: Three-dimensional planning predicted the need for femoral and tibial augments in 22 (78.6%) cases at both the tibial and femoral components, while 2D planning correctly predicted the need for augmentation in 17 (60.7%) for the tibial side and 18 (64.3%) for the femoral side. The Cohen's kappa demonstrated a significant agreement between the 3D planning for the femoral metal block and the intraoperative requirement (kappa=0.553), whereas 2D planning showed only nonsignificant poor agreement (kappa=0.083). In contrast, the agreement between 2D or 3D preoperative planning for tibial augment and the intraoperative requirement was nonsignificant (kappa=0.130 and kappa=0.158, respectively). On the femoral side, 2D planning showed only a fair nonsignificant correlation (r=0.35, p=0.069), whereas 3D planning exhibited substantial agreement with the actual thickness of the implanted augment (r=0.65, p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Unit of Orthopaedic Surgery, Department of Public Health, School of Medicine, Federico II University, Naples, Italy. vincenzo.dematteo@unina.it.
Zitieren
APA
Balato, G., De Matteo, V., Guarino, A., De Mauro, D., Baldi, D., Cavaliere, C., Salvatore, M., Citak, M., & Mariconda, M. (2024). A comparison between 3D printed models and standard 2D planning in the use of metal block augments in revision knee arthroplasty. Joint Diseases and Related Surgery. https://doi.org/10.52312/jdrs.2024.1591
Vancouver
Balato G, De Matteo V, Guarino A, De Mauro D, Baldi D, Cavaliere C, et al. A comparison between 3D printed models and standard 2D planning in the use of metal block augments in revision knee arthroplasty. Joint Diseases and Related Surgery. 2024. doi:10.52312/jdrs.2024.1591
BibTeX
@article{Balato2024,
author = {Balato, Giovanni and De Matteo, Vincenzo and Guarino, Amedeo and De Mauro, Domenico and Baldi, Dario and Cavaliere, Carlo and Salvatore, Marco and Citak, Mustafa and Mariconda, Massimo},
title = {A comparison between 3D printed models and standard 2D planning in the use of metal block augments in revision knee arthroplasty},
journal = {Joint Diseases and Related Surgery},
year = {2024},
doi = {10.52312/jdrs.2024.1591}
}
EUVIMED