EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Laboratory validation of patient-specific templating for total knee arthroplasty

Mahmoud A Hafez iD, Arne Jansen, Frank Portheine, Branislav Jaramaz iD

Scientific Reports · 2025

DOI: 10.1038/s41598-024-77794-9 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Scientific Reports, 2025. Verfasst von Mahmoud A Hafez und 3 weiteren Autor:innen. Beteiligte Einrichtung: The Orthopaedic Department, Faculty of Medicine, October 6 University, Giza, Egypt. mhafez@msn.com. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Surgery, Computer-Assisted. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: 6 October University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Patient-specific templating (PST), which is a sister procedure to patient-specific instrumentation (PSI) but hospital-based, is relatively less complex and less expensive than robotics and navigation. However, there are some concerns about the PST including the process of preoperative planning, 3D printing and material, positioning of PST intraoperatively, availability, and clinical value. The purpose of this study was to validate the technical accuracy and reliability of the PST technique in the lab and to report the outcomes of clinical application. To test the reliability of the PST technique, five observers positioned the PST templates five times over the distal femur and proximal tibial whilst a navigation system was used to measure the level of bone cutting, coronal and sagittal alignment, and rotation in both femur and tibia. The mean alignment error in all planes was 0.67° (maximum 2.5°). Concerning the bone (femoral and tibial) cutting, the mean error was 0.32 mm (maximum 1 mm). The qualitative and quantitative analysis showed an overall agreement between observers (p < 0.05). The laboratory part of this study showed that the positioning of the PST over the proximal tibia and distal femur during TKA is reliable. There were statistically insignificant intraobserver and interobserver variations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeSurgery, Computer-AssistedHumansTibiaFemurFemaleMaleReproducibility of ResultsAgedPrinting, Three-DimensionalMiddle AgedKnee Joint

Stichwörter der Autor:innen

Custom-madeCutting guidesPatient-specific templatingTotal knee arthroplastyTotal knee replacement

Autor:innen und Institutionen

  • The Orthopaedic Department, Faculty of Medicine, October 6 University, Giza, Egypt. mhafez@msn.com.
  • Helmholtz-Institute of Biomedical Engineering and SurgiTaix, Aachen, Germany.
  • Robotics Institute, Carnegie Mellon University, 5000 Forbes Avenue, Pittsburgh, PA, 15213, USA.

ORCID-Profile: Mahmoud A Hafez, Branislav Jaramaz

Förderung

  • 6 October University

Zitieren

APA

Hafez, M. A., Jansen, A., Portheine, F., & Jaramaz, B. (2025). Laboratory validation of patient-specific templating for total knee arthroplasty. Scientific Reports. https://doi.org/10.1038/s41598-024-77794-9

Vancouver

Hafez MA, Jansen A, Portheine F, Jaramaz B. Laboratory validation of patient-specific templating for total knee arthroplasty. Scientific Reports. 2025. doi:10.1038/s41598-024-77794-9

BibTeX
@article{Hafez2025,
  author = {Hafez, Mahmoud A and Jansen, Arne and Portheine, Frank and Jaramaz, Branislav},
  title = {Laboratory validation of patient-specific templating for total knee arthroplasty},
  journal = {Scientific Reports},
  year = {2025},
  doi = {10.1038/s41598-024-77794-9}
}
Kostenlos starten →