Abstract (Originalsprache)

Introduction

This study aims to assess the accuracy of glenohumeral joint injections through an anterosuperior approach using anatomical landmarks as a guide and arthroscopic visualization as the control method and to evaluate whether there is any association between accuracy, the physicians training, and the patient’s pathology. Materials and Methods: A sample size of 124 patients was calculated. A prospective cohort study including 164 consecutive patients was conducted. All patients over 18 years of age who underwent shoulder arthroscopy during the study period were included. A needle was placed using an anterosuperior approach before the beginning of the surgery alternating between a shoulder surgeon and a resident. Direct visualization through a posterior arthroscopic view was used to verify correct needle placement. Each case was classified as success or failure based on the arthroscopic intra-articular visualization of the needle. Univariate and multivariate analyses were performed to evaluate the relationship between injection accuracy, operator experience, and patient pathology. A p-value less than 0.05 was considered statistically significant.

Results

Of the 164 needles placed, 131 were intra-articular, giving a total correct placement rate of 80% (95% CI, 73–86%). Experts had an accuracy of 88%, compared to a precision rate of 72% for residents (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shoulder JointHumansProspective StudiesInjections, Intra-ArticularFemaleMaleMiddle AgedArthroscopyAdultAged

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Italian Hospital of Buenos Aires, Buenos Aires, Argentina.
  • Shoulder Unit, Department of Orthopaedic Surgery, Italian Hospital of Buenos Aires, Buenos Aires, Argentin.

Zitieren

APA

Dardanelli, P., Brandariz, R., Tanoira, I., Rossi, L., & Ranalletta, M. (2024). Accuracy of Anterior Shoulder Injections Without Image Guidance: A Prospective Controlled Study. Surgical Technology Online. https://doi.org/10.52198/24.sti.44.os1771

Vancouver

Dardanelli P, Brandariz R, Tanoira I, Rossi L, Ranalletta M. Accuracy of Anterior Shoulder Injections Without Image Guidance: A Prospective Controlled Study. Surgical Technology Online. 2024. doi:10.52198/24.sti.44.os1771

BibTeX
@article{Dardanelli2024,
  author = {Dardanelli, Pablo and Brandariz, Rodrigo and Tanoira, Ignacio and Rossi, Luciano and Ranalletta, Maximiliano},
  title = {Accuracy of Anterior Shoulder Injections Without Image Guidance: A Prospective Controlled Study},
  journal = {Surgical Technology Online},
  year = {2024},
  doi = {10.52198/24.sti.44.os1771}
}
Kostenlos starten →