EUVIMEDEUVIMED entdecken
Crossref

Efficiency of Axillary Bolster Use for Ultrasound‐Guided Glenohumeral Joint Injection in MR Arthrography

Zakir Sakci, Hayri Ogul iD, Kutsi Tuncer, Serhat Kaya, Alper Kiziloglu, Gokhan Polat, Mecit Kantarci

Journal of Clinical Ultrasound · 2025

DOI: 10.1002/jcu.24018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Ultrasound, 2025. Verfasst von Zakir Sakci und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Umraniye Training and Research Hospital, Istanbul, Turkey. Hauptthemen laut MEDLINE: Shoulder Joint, Ultrasonography, Interventional, Contrast Media, Magnetic Resonance Imaging. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to prospectively evaluate the accuracy of the ultrasonography (US)‐guided posterior injection technique using an axillary bolster for magnetic resonance (MR) arthrography of the shoulder joint. Materials and Methods This study included 60 patients (30 US‐guided injections with an axillary bolster, 30 US‐guided injections without an axillary bolster). There were 37 men and 23 women whose ages ranged from 17 to 64 years (mean, 36.87 years). All procedures were performed by two radiologists with less than 1 year of experience in arthrographic procedures. The accuracy of the two injection techniques was compared. Extraarticular contrast material leak was graded according to the MR arthrography findings. The number of injection attempts and the effect of contrast material extravasation rate on diagnostic quality were recorded.

Results

There were no significant differences between US‐guided punctures with and without an axillary bolster in regard to pain ( p = 0.39). Injections with an axillary bolster had a higher likelihood of success on the first attempt ( p = 0.0031). Complete extravasation in the US‐guided posterior approach technique without an axillary bolster was significantly higher than the US‐guided posterior injection technique with an axillary bolster ( p < 0.0001).

Conclusion

Although there is no significant difference in pain scores for both techniques, complete contrast material extravasation is seen at a higher rate in the US‐guided posterior approach injection technique without the use of an axillary bolster compared to the technique used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shoulder JointUltrasonography, InterventionalContrast MediaMagnetic Resonance ImagingArthrographyHumansFemaleMaleAdultMiddle AgedAdolescentInjections, Intra-ArticularProspective StudiesYoung AdultAxilla

Stichwörter der Autor:innen

arthrographyglenohumeral jointmagnetic resonance imagingultrasound

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Umraniye Training and Research Hospital, Istanbul, Turkey.
  • Department of Radiology, Medical Faculty, Istanbul Medipol University, Istanbul, Turkey.
  • Department of Orthopedic Surgery, Medical Faculty, Altinbas University, Istanbul, Turkey.
  • Department of Radiology, Medical Faculty, Ataturk University, Erzurum, Turkey.

ORCID-Profile: Hayri Ogul

Zitieren

APA

Sakci, Z., Ogul, H., Tuncer, K., Kaya, S., Kiziloglu, A., Polat, G., & Kantarci, M. (2025). Efficiency of Axillary Bolster Use for Ultrasound‐Guided Glenohumeral Joint Injection in MR Arthrography. Journal of Clinical Ultrasound. https://doi.org/10.1002/jcu.24018

Vancouver

Sakci Z, Ogul H, Tuncer K, Kaya S, Kiziloglu A, Polat G, et al. Efficiency of Axillary Bolster Use for Ultrasound‐Guided Glenohumeral Joint Injection in MR Arthrography. Journal of Clinical Ultrasound. 2025. doi:10.1002/jcu.24018

BibTeX
@article{Sakci2025,
  author = {Sakci, Zakir and Ogul, Hayri and Tuncer, Kutsi and Kaya, Serhat and Kiziloglu, Alper and Polat, Gokhan and Kantarci, Mecit},
  title = {Efficiency of Axillary Bolster Use for Ultrasound‐Guided Glenohumeral Joint Injection in MR Arthrography},
  journal = {Journal of Clinical Ultrasound},
  year = {2025},
  doi = {10.1002/jcu.24018}
}
Kostenlos starten →