EUVIMEDEUVIMED entdecken
Crossref

Evaluation of an Initial Robotic-Assisted Direct Anterior Approach Cohort Receiving a New Short Metaphyseal Filling Collared Femoral Implant

Joshua P Rainey, Jeremy M Gililland, Kevin Marchand, Kelly Taylor, Michael A Mont, Robert C Marchand

Surgical Technology Online · 2024

DOI: 10.52198/24.sti.44.os1759 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Surgical Technology Online, 2024. Verfasst von Joshua P Rainey und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Arthroplasty, Replacement, Hip, Hip Prosthesis, Femur.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Shorter, metaphyseal-filling collared stems have become popular with the direct anterior approach (DAA), based on their ease of broaching and insertion through less invasive surgical exposures. To aid with the DAA, robotic-assisted technology provides three-dimensional computed tomography (CT) preoperative planning and intraoperative guidance to accurately assess stem version. With other femoral stems, this has been shown to provide more accurate implant planning and improved patient outcomes. The purpose of this study was to understand femoral stem placement predictability and patient outcomes for a newly designed metaphyseal-filling collared stem system through a DAA in combination with a robotic-assisted system during a single surgeon’s initial cases. Materials and Methods: A single high-volume surgeon, experienced with robotic-assisted DAA total hip arthroplasty (THA), adopted the use of a metaphyseal-filling collared stem. Intraoperative data and patient outcomes up to six months postoperative were collected prospectively during the surgeon’s first 123 cases. Student’s t-tests (α=0.05) were used for statistical comparisons. Intraoperative and radiographic assessments were performed for all 123 cases.

Results

The estimated version with neck-cut view of the robotic-assisted system was 13.81 ± 3.81°. The final version measurement captured with the robotic-assisted system was 16.56 ± 6.61°. The difference between the estimated version and robotic-assisted measured version was, on average, 2.68 ± 5.7° (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Robotic Surgical ProceduresArthroplasty, Replacement, HipHip ProsthesisFemurHumansMaleFemaleMiddle AgedAgedTomography, X-Ray ComputedProsthesis DesignTreatment OutcomeAdultAged, 80 and over

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, University of Utah, Salt Lake City, Utah.
  • Northwell Health Orthopaedics, Lenox Hill Hospital, CUNY School of Medicine, New York, New York.
  • Orthopedics Rhode Island, Providence, Rhode Island.
  • Rubin Institute for Advanced Orthopaedics, Sinai Hospital of Baltimore, Baltimore, Maryland.
  • South County Orthopaedics, Orthopaedics Rhode Island Wakefield, Rhode Island.

Zitieren

APA

Rainey, J. P., Gililland, J. M., Marchand, K., Taylor, K., Mont, M. A., & Marchand, R. C. (2024). Evaluation of an Initial Robotic-Assisted Direct Anterior Approach Cohort Receiving a New Short Metaphyseal Filling Collared Femoral Implant. Surgical Technology Online. https://doi.org/10.52198/24.sti.44.os1759

Vancouver

Rainey JP, Gililland JM, Marchand K, Taylor K, Mont MA, Marchand RC. Evaluation of an Initial Robotic-Assisted Direct Anterior Approach Cohort Receiving a New Short Metaphyseal Filling Collared Femoral Implant. Surgical Technology Online. 2024. doi:10.52198/24.sti.44.os1759

BibTeX
@article{Rainey2024,
  author = {Rainey, Joshua P and Gililland, Jeremy M and Marchand, Kevin and Taylor, Kelly and Mont, Michael A and Marchand, Robert C},
  title = {Evaluation of an Initial Robotic-Assisted Direct Anterior Approach Cohort Receiving a New Short Metaphyseal Filling Collared Femoral Implant},
  journal = {Surgical Technology Online},
  year = {2024},
  doi = {10.52198/24.sti.44.os1759}
}
Kostenlos starten →