Comparative analysis of CT-based and 2D digital templating in robotic hip arthroplasty
HIP International · 2026
DOI: 10.1177/11207000251352128 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift HIP International, 2026. Verfasst von Duncan E J Whittaker und 4 weiteren Autor:innen. Beteiligte Einrichtung: Trauma and Orthopaedics, Aberdeen Royal Infirmary, Aberdeen, UK. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Hip, Robotic Surgical Procedures, Tomography, X-Ray Computed, Hip Prosthesis. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Background
Preoperative templating in Total Hip Arthroplasty (THA) is an essential tool in arthroplasty surgery. This study investigates the efficacy of CT-based templating in robotic total hip arthroplasty (rTHA) compared to traditional 2D digital x-ray templating and evaluates intra-observer variability among 3 arthroplasty consultants.
Methods
A total of 37 patients scheduled for primary hybrid rTHA using the Mako robot (Stryker) were included in the study. Independent, 2D digital templating (Materialise Orthoview) was performed by 3 experienced orthopaedic arthroplasty consultants, and the results were compared with a CT templating system (Stryker) and the postoperative implant size after CT based rTHA. Intra-observer reliability among the surgeons was determined using Fleiss’ Kappa, individual surgeons were compared to the CT-templating system and the postoperative implant using Cohen’s Kappa.
Results
Intra-observer reliability among surgeons was low, with significant variability and no variable showing strong agreement. 2D digital templating demonstrated poor predictive value for the post-operative implant size. There was considerable variance between surgeons and their agreement with the CT demonstrated superior predictive values for the postoperative implants as compared to the 2D digital templating technique.
Conclusions
This study suggests that the predictive value of the CT templating system was superior to that of surgeon based 2D digital templating for CT templating based rTHA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Trauma and Orthopaedics, Aberdeen Royal Infirmary, Aberdeen, UK.
- Institute of Applied Health Sciences, University of Aberdeen, Aberdeen, UK.
- Fife Orthopaedic National Treatment Centre, Fife, UK.
ORCID-Profile: Duncan E J Whittaker
Zitieren
APA
Whittaker, D. E. J., Medlock, G., Neilly, D. W., Diffley, T. I., & Rehman, H. (2026). Comparative analysis of CT-based and 2D digital templating in robotic hip arthroplasty. HIP International. https://doi.org/10.1177/11207000251352128
Vancouver
Whittaker DEJ, Medlock G, Neilly DW, Diffley TI, Rehman H. Comparative analysis of CT-based and 2D digital templating in robotic hip arthroplasty. HIP International. 2026. doi:10.1177/11207000251352128
BibTeX
@article{Whittaker2026,
author = {Whittaker, Duncan E J and Medlock, Gareth and Neilly, David W and Diffley, Thomas I and Rehman, Haroon},
title = {Comparative analysis of CT-based and 2D digital templating in robotic hip arthroplasty},
journal = {HIP International},
year = {2026},
doi = {10.1177/11207000251352128}
}
EUVIMED