Fachartikel in der Zeitschrift Surgical Technology Online, 2023. Verfasst von Guglielmo Stefanelli und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiac Surgery, Hesperia Hospital, Modena, Italy. Hauptthemen laut MEDLINE: Heart Valve Prosthesis, Aortic Valve, Heart Valve Prosthesis Implantation, Prosthesis Design.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The purpose of this study was to evaluate the long-term clinical and hemodynamic results in patients affected by severe aortic valve disease after aortic valve replacement with third-generation stentless aortic prostheses (3F® stentless equine pericardial [Medtronic plc, Minneapolis Minnesota] and Pericarbon Freedom™ stentless bovine pericardial [LivaNova plc, London, United Kingdom]) and to analyze the benefits and the drawbacks associated to their use. Materials and Methods: Between June, 2003 and Sept, 2015 a cohort of 548 consecutive patients affected by aortic valve disease received an aortic valve replacement using a last-generation stentless pericardial aortic prosthesis at our unit. Respectively, 322 patients received a Pericarbon Freedom™ and 226 received a 3F® aortic valve. Size ranged between 19 and 29, with prevalence of 23 and 25 devices. Mean age at operation was 71± 11 years, 57% of patients were males, the mean logistic EuroScore was 8.9 ± 7.2 and 44.2% received concomitant procedures. The mean extracorporeal circulation (ECC) time was 119.2 ± 40.6. The mean cross clamp time was 90.5’ ± 21.4’. In 30 patients, the aortic prosthesis was included in a Dacron tube straight graft for a Bentall operation.

Results

Early/in-hospital mortality was 2.55% (14 cases) for the entire cohort. In patients receiving isolated aortic valve replacement (AVR), it was 0.91% (5 cases). Follow up ranged between six months and 12 years (median follow-up time: 6.77 years). During follow up, 137 patients died of all causes (25%), of whom 32 patients died of cardiac causes (5.8%). Cardiac survival probability was 91% at 12 years. All surviving patients were in NYHA class I at last follow up. Actuarial freedom from structural valve deterioration was 86% at 12 years. Freedom from endocarditis was 95% at 12 years. Freedom from a valve-related reoperation at 12 years follow up was 95%. Mean residual transprosthetic gradient at 12 years was 10.3 ± 4.8MmHg.

Conclusions

Last-generation stentless pericardial valves offer excellent hemodynamics and adequate durability and freedom from structural deterioration at 12 years follow up. The implantation technique of a stentless valve is a little more demanding when compared to a stented valve, but it can be easily reproduced after minimal training. Incidence of endocarditis and thromboembolic events is low and comparable to stented pericardial valves. Young and active patients, and patients with large BSA where a patient-prosthesis mismatch may be anticipated are, in our opinion, ideal candidates to receive these kinds of valves.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart Valve ProsthesisAortic ValveHeart Valve Prosthesis ImplantationProsthesis DesignHumansMaleFemaleAgedMiddle AgedTreatment OutcomeAged, 80 and overBioprosthesisAortic Valve DiseaseRetrospective Studies

Autor:innen und Institutionen

  • Department of Cardiac Surgery, Hesperia Hospital, Modena, Italy.
  • Department of Cardiology, University Hospital, Modena, Italy.
  • Department of Cardiology, Ospedale Vignola Hospital, Vignola, Italy.
  • Anesthesiology Department, Hesperia Hospital, Modena, Italy.
  • Department of Cardiac Surgery, European Hospital, Rome, Italy.

Zitieren

APA

Stefanelli, G., Sgura, F., Menozzi, F. M., Meli, M., & Weltert, L. (2023). Long-Term Results After Aortic Valve Replacement with Last-Generation Stentless Prostheses. Surgical Technology Online. https://doi.org/10.52198/23.sti.43.cv1683

Vancouver

Stefanelli G, Sgura F, Menozzi FM, Meli M, Weltert L. Long-Term Results After Aortic Valve Replacement with Last-Generation Stentless Prostheses. Surgical Technology Online. 2023. doi:10.52198/23.sti.43.cv1683

BibTeX
@article{Stefanelli2023,
  author = {Stefanelli, Guglielmo and Sgura, Fabio and Menozzi, Francesca M and Meli, Marco and Weltert, Luca},
  title = {Long-Term Results After Aortic Valve Replacement with Last-Generation Stentless Prostheses},
  journal = {Surgical Technology Online},
  year = {2023},
  doi = {10.52198/23.sti.43.cv1683}
}
Kostenlos starten →