EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

An adjustable-rate user-printable rain gauge calibrator

Matthew Tippett-Vannini, Paul Gasper, Aiden Hosford, John Selker

Geoscientific Instrumentation, Methods and Data Systems · 16.11.2026 · 15 (2) · 323-334

DOI: 10.5194/gi-15-323-2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Geoscientific Instrumentation, Methods and Data Systems, online erschienen am 16.11.2026. Verfasst von Matthew Tippett-Vannini und 3 weiteren Autor:innen. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate precipitation measurement is essential. However, calibration of field-deployed rain gauges remains a challenge. Many methods require laboratory conditions, costly commercial equipment, or instruments designed for specific rain gauges, which cannot accommodate smaller-diameter gauges. We introduce the Adjustable-Rate 3D Printed Rain Gauge Calibrator (AR3D) , a low-cost, open-source device designed for in situ calibration of rain gauges. The AR3D introduces three innovations: (1) an adjustable screw valve, enabling flow rate tuning from 0.15–16 mL min −1 (equivalent rainfall rates 1.3–141.2 mm h −1 , for a 9.3 cm diameter gauge), accommodating the lower flow rates needed for smaller rain gauges and allowing for validation across a wide range of rainfall rates; (2) a compact and durable design developed with low-volume reservoirs and elimination of degradable parts; and (3) an integrated pyranometer cover to generate automatic calibration event signals. We evaluated the AR3D using gravimetric tests, constant-rate stability tests, device-to-device equivalence tests, and field comparisons. Laboratory gravimetric tests of the AR3D demonstrate its ability to deliver volumes of water accurately with an average error of 0.11 % (comparable to ISO Class B tolerances for plastic volumetric flasks) at flow rates within ±5 % equivalence across independent devices, with a coefficient of variation (CV) below 5 %. The AR3D has been successfully deployed to weather stations in Kenya and the United States. Field validation of the AR3D with a single setting resulted in a flow rate CV of 8.7 %. The AR3D enabled the identification of properly functioning rain gauges, as well as an under-reporting station. The total cost of material and labor to build an AR3D is approximately USD 12.

Zitieren

APA

Tippett-Vannini, M., Gasper, P., Hosford, A., & Selker, J. (2026). An adjustable-rate user-printable rain gauge calibrator. Geoscientific Instrumentation, Methods and Data Systems, 15(2), 323-334. https://doi.org/10.5194/gi-15-323-2026

Vancouver

Tippett-Vannini M, Gasper P, Hosford A, Selker J. An adjustable-rate user-printable rain gauge calibrator. Geoscientific Instrumentation, Methods and Data Systems. 2026;15(2):323-334. doi:10.5194/gi-15-323-2026

BibTeX
@article{TippettVannini2026,
  author = {Tippett-Vannini, Matthew and Gasper, Paul and Hosford, Aiden and Selker, John},
  title = {An adjustable-rate user-printable rain gauge calibrator},
  journal = {Geoscientific Instrumentation, Methods and Data Systems},
  year = {2026},
  volume = {15},
  number = {2},
  pages = {323--334},
  doi = {10.5194/gi-15-323-2026}
}
Kostenlos starten →