EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

Kalibrasi Temperature Gauge Menggunakan Oil Bath Temperature Calibrator CTB9500 Pada Industri Kilang

Dillon Diandri, Farah Sukma Maulida, Suka Handaja

Journal of Instrumentation and Hardware · 20.06.2026 · 4 (1) · 13-21

DOI: 10.53026/2fv6hj95 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Instrumentation and Hardware, online erschienen am 20.06.2026. Verfasst von Dillon Diandri und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study aims to analyze the calibration performance of temperature gauges using a WIKA CTB9500 oil bath calibrator—which features a stability of ±0.05°C and an accuracy of ±0.3°C—to improve temperature measurement accuracy in refinery processes. An experimental approach was employed, involving the calibration of 45 temperature gauge units from various brands with a measurement range of 0–60°C. The calibration process utilized a pre-cycle method at 0°C and 60°C, followed by testing in the sequence: 20°C → 30°C → 40°C → 30°C → 20°C. The calibration data were analyzed to determine error, hysteresis, and repeatability, with a pass criterion of a ±1°C tolerance. The results indicate that the CTB9500 was able to detect an average measurement error of 2.1°C in the "as-found" condition. Statistical analysis shows that 82% of the instruments met the ±1°C tolerance after calibration, while 18% were deemed unfit for further use (scrapped). Instruments in service for more than two years exhibited a drift of 0.38°C per month

Zitieren

APA

Diandri, D., Maulida, F. S., & Handaja, S. (2026). Kalibrasi Temperature Gauge Menggunakan Oil Bath Temperature Calibrator CTB9500 Pada Industri Kilang. Journal of Instrumentation and Hardware, 4(1), 13-21. https://doi.org/10.53026/2fv6hj95

Vancouver

Diandri D, Maulida FS, Handaja S. Kalibrasi Temperature Gauge Menggunakan Oil Bath Temperature Calibrator CTB9500 Pada Industri Kilang. Journal of Instrumentation and Hardware. 2026;4(1):13-21. doi:10.53026/2fv6hj95

BibTeX
@article{Diandri2026,
  author = {Diandri, Dillon and Maulida, Farah Sukma and Handaja, Suka},
  title = {Kalibrasi Temperature Gauge Menggunakan Oil Bath Temperature Calibrator CTB9500 Pada Industri Kilang},
  journal = {Journal of Instrumentation and Hardware},
  year = {2026},
  volume = {4},
  number = {1},
  pages = {13--21},
  doi = {10.53026/2fv6hj95}
}
Kostenlos starten →