Energy and Environmental Analysis of R-134a vs R-600a in a Vapor Compression Cycle for Hot Regions

Syed Ali Murtaza, Farah Naz, Aown Muhammad Shah

Pakistan Journal of Engineering and Technology · 21.08.2026 · 9 (2) · 17-22

DOI: 10.51846/vol9iss2pp17-22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pakistan Journal of Engineering and Technology, online erschienen am 21.08.2026. Verfasst von Syed Ali Murtaza und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With the growing concern over sustainable energy in Pakistan is very critical so this paper presents the performance of Tetrafluoroethane (R134a) and Isobutane(R600a). Refrigerants are evaluated under specific environmental and desired space temperatures using the experimentally and numerically through MATLAB Simulation. As a limitation of this work, the MATLAB-based simulation analyses the Coefficient of Performance (COP), cooling load, and power input for a vapor-compression refrigeration system. In this study, the Numerically/Experimentally analyse the thermodynamic data, including enthalpy values based on ASHRAE standards, was utilized to predict refrigerating effect and compressor work across a range of evaporator temperatures (−5°C, 10°C, 15°C, 20°C) and room temperatures (35°C to 55°C), for the specific region of Multan, Pakistan. Several Studies have investigated this, but my outcomes are compared to prior literature, including Aized et al. (2022) and Sánchez et al. (2022), to validate findings and provide context for the suitability of low-GWP alternatives. The numerical and experimental results show excellent agreement, with the percentage error data approximately 1- 1.8% for both the calculation of COP and COST of Electricity. The findings of this research elaborate that isobutane (R600a) is outperform as compared the tetrafluroethane(R134a) for the hot climate of Multan, Pakistan, and transitioning to sustainable refrigerant solutions.

Zitieren

APA

Murtaza, S. A., Naz, F., & Shah, A. M. (2026). Energy and Environmental Analysis of R-134a vs R-600a in a Vapor Compression Cycle for Hot Regions. Pakistan Journal of Engineering and Technology, 9(2), 17-22. https://doi.org/10.51846/vol9iss2pp17-22

Vancouver

Murtaza SA, Naz F, Shah AM. Energy and Environmental Analysis of R-134a vs R-600a in a Vapor Compression Cycle for Hot Regions. Pakistan Journal of Engineering and Technology. 2026;9(2):17-22. doi:10.51846/vol9iss2pp17-22

BibTeX
@article{Murtaza2026,
  author = {Murtaza, Syed Ali and Naz, Farah and Shah, Aown Muhammad},
  title = {Energy and Environmental Analysis of R-134a vs R-600a in a Vapor Compression Cycle for Hot Regions},
  journal = {Pakistan Journal of Engineering and Technology},
  year = {2026},
  volume = {9},
  number = {2},
  pages = {17--22},
  doi = {10.51846/vol9iss2pp17-22}
}