EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing Energy Performance and Environmental Impact of Low GWP Vapor Compression Chilled Water Systems

Rami Mansouri, Baby-Jean Robert Mungyeko Bisulandu, Adrian Ilinca

Energies · 16.06.2023 · 16 (12) · 4751

DOI: 10.3390/en16124751 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies, online erschienen am 16.06.2023. Verfasst von Rami Mansouri und 2 weiteren Autor:innen. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Quebec at Rimouski (UQAR), Wind Energy Research Laboratory (LREE), Professor Adrian Ilinca.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The global concern regarding the environmental repercussions of refrigerants has escalated due to their adverse effects. These substances deplete the ozone layer and intensify the greenhouse effect. International agreements such as the Montreal and Kyoto Protocols and COP21 have imposed restrictions on refrigerants with high global warming potential (GWP) to address these issues. This study aims to explore the feasibility, energy efficiency, and environmental impact of utilizing the HFO (hydrofluoric-olefin) refrigerant R1234ze as a substitute for HFCs (hydrofluoric-carbon) (R134a, R407C, and R410A) and HCFCs (R22) in air-cooled vapor compression refrigeration and air conditioning systems. To determine their effectiveness, we evaluate the energy performance of various refrigerant operating cycles across a wide range of ambient and evaporating temperatures. Additionally, we conduct environmental impact analyses based on the total equivalent warming impact (TEWI) parameter calculated for commercially available chillers that utilize the fluids mentioned above. Our findings indicate that vapor compression chilled water systems employing R1234ze exhibit the highest performance coefficient and the lowest annual TEWI.

Förderung

  • University of Quebec at Rimouski (UQAR)
  • Wind Energy Research Laboratory (LREE)
  • Professor Adrian Ilinca

Zitieren

APA

Mansouri, R., Bisulandu, B. R. M., & Ilinca, A. (2023). Assessing Energy Performance and Environmental Impact of Low GWP Vapor Compression Chilled Water Systems. Energies, 16(12), 4751. https://doi.org/10.3390/en16124751

Vancouver

Mansouri R, Bisulandu BRM, Ilinca A. Assessing Energy Performance and Environmental Impact of Low GWP Vapor Compression Chilled Water Systems. Energies. 2023;16(12):4751. doi:10.3390/en16124751

BibTeX
@article{Mansouri2023,
  author = {Mansouri, Rami and Bisulandu, Baby-Jean Robert Mungyeko and Ilinca, Adrian},
  title = {Assessing Energy Performance and Environmental Impact of Low GWP Vapor Compression Chilled Water Systems},
  journal = {Energies},
  year = {2023},
  volume = {16},
  number = {12},
  pages = {4751},
  doi = {10.3390/en16124751}
}
Kostenlos starten →