Percutaneous interventional removal of the broken catheter during angiography
Journal of Radiology in Medicine · 2024
DOI: 10.51271/jrm-0004 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiology in Medicine, 2024. Verfasst von Muhammed Karadeniz und 1 weiteren Autor:innen.
Abstract (Originalsprache)
Catheter rupture during coronary angiography is very rare complication. Generally, this broken catheter piece can be removed with a snareloop, but sometimes in cases where the broken piece is large in diameter, it may not be caught with a snareloop. In this case, the catheter piece that could not be caught with a snare loop was removed by catching it with a manual snare using a 0.014 inch guide wire.
Zitieren
APA
Karadeniz, M., & Rukiye, G. (2024). Percutaneous interventional removal of the broken catheter during angiography. Journal of Radiology in Medicine. https://doi.org/10.51271/jrm-0004
Vancouver
Karadeniz M, Rukiye G. Percutaneous interventional removal of the broken catheter during angiography. Journal of Radiology in Medicine. 2024. doi:10.51271/jrm-0004
BibTeX
@article{Karadeniz2024,
author = {Karadeniz, Muhammed and Rukiye, Gönen},
title = {Percutaneous interventional removal of the broken catheter during angiography},
journal = {Journal of Radiology in Medicine},
year = {2024},
doi = {10.51271/jrm-0004}
}
EUVIMED