Removal of a broken percutaneous transhepatic biliary drainage catheter by cholangioscopy through a lumen-apposing metal stent used for choledochoduodenostomy

Il Sang Shin, Yeon Han Song, Jong Ho Moon, Yun Nah Lee, Jun Ho Myeong

Endoscopy · 01.12.2023 · 55 (S 01 S 01) · E373-E374

DOI: 10.1055/a-1996-0223 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.12.2023. Verfasst von Il Sang Shin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Digestive Disease Center and Research Institute, Department of Internal Medicine, SoonChunHyang University School of Medicine, Bucheon, Korea. Hauptthemen laut MEDLINE: Choledochostomy, Catheterization. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: SoonChunHyang University Research Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CDS) using a lumen-apposing metal stent (LAMS) is an alternative procedure for biliary decompression in patients with distal malignant biliary strictures [ 1 ] [ 2 ] [ 3 ] [ 4 ]. Although this approach results in a new connecting passage into the bile duct, there are few reports of direct visualization into the bile duct through a LAMS used for CDS [ 5 ]. We present a procedure for the removal of a broken percutaneous transhepatic biliary drainage (PTBD) catheter through a LAMS used for CDS. A 53-year-old woman with a history of schizophrenia was admitted with abdominal pain and jaundice. She had been diagnosed with pancreatic head cancer 1 month previously and underwent PTBD to decompress the malignant biliary strictures. Two days prior to admission, the patient had cut the PTBD catheter with a knife, after which she developed abdominal pain and jaundice. Computed tomography revealed the distal end of the broken catheter buried in the abdominal wall ([ Fig. 1 ]). Removal of the catheter via a percutaneous tract was not possible. Fig. 1 Computed tomographic scan showing the broken percutaneous transhepatic biliary drainage catheter buried in the abdominal wall. Endoscopic retrograde cholangiopancreatography was also not possible, because pancreatic cancer had obstructed the second duodenal portion. Instead, EUS-CDS was performed using a LAMS (Spaxus; Taewoong Medical, Ilsan, South Korea). Four days later, direct peroral cholangioscopy using a multibending ultraslim endoscope (CHF-Y0010; Olympus Medical Systems, Tokyo, Japan) was performed through the LAMS ([ Fig. 2 a, b ]). Endoscopy revealed the broken catheter in the left intrahepatic bile duct. The catheter was grasped using a 2-mm forceps ([ Fig. 2 c ]) and successfully removed via endoscopic withdrawal through the LAMS ([ Fig. 2 d ]; [ Video 1 ]). Fig. 2 Removal of the broken percutaneous transhepatic biliary drainage (PTBD) catheter by direct peroral cholangioscopy using a multibending ultraslim endoscope through a lumen-apposing metal stent (LAMS). a, b Radiographic images showing ( a ) insertion of the multibending ultraslim endoscope into the intrahepatic duct through the LAMS and ( b ) withdrawal of the PTBD catheter through the LAMS. c Endoscopic image of the PTBD catheter being grasped by a 2-mm forceps. d The successfully removed broken PTBD catheter. Video 1 Removal of a broken percutaneous transhepatic biliary drainage catheter by direct peroral cholangioscopy using a multibending ultraslim endoscope through a lumen-apposing metal stent used for choledochoduodenostomy. Download Video This report describes the safe removal of a broken PTBD catheter via peroral cholangioscopy after EUS-CDS. The LAMS served as a connection route enabling a less invasive approach. The creation of an anastomosis between the enteric and biliary systems using a LAMS not only allows biliary drainage but also provides access for advanced endoscopic intervention. Endoscopy_UCTN_Code_CPL_1AK_2AH Endoscopy E-Videos https://eref.thieme.de/e-videos Endoscopy E-Videos is an open access online section, reporting on interesting cases and new techniques in gastroenterological endoscopy. All papers include a high quality video and all contributions are freely accessible online. Processing charges apply (currently EUR 375), discounts and wavers acc. to HINARI are available. This section has its own submission website at https://mc.manuscriptcentral.com/e-videos Publication History Article published online: 16 January 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CholedochostomyCatheterizationHumansStentsDrainageCatheters

Autor:innen und Institutionen

  • Digestive Disease Center and Research Institute, Department of Internal Medicine, SoonChunHyang University School of Medicine, Bucheon, Korea.

Förderung

  • SoonChunHyang University Research Fund

Zitieren

APA

Shin, I. S., Song, Y. H., Moon, J. H., Lee, Y. N., & Myeong, J. H. (2023). Removal of a broken percutaneous transhepatic biliary drainage catheter by cholangioscopy through a lumen-apposing metal stent used for choledochoduodenostomy. Endoscopy, 55(S 01 S 01), E373-E374. https://doi.org/10.1055/a-1996-0223

Vancouver

Shin IS, Song YH, Moon JH, Lee YN, Myeong JH. Removal of a broken percutaneous transhepatic biliary drainage catheter by cholangioscopy through a lumen-apposing metal stent used for choledochoduodenostomy. Endoscopy. 2023;55(S 01 S 01):E373-E374. doi:10.1055/a-1996-0223

BibTeX
@article{Shin2023,
  author = {Shin, Il Sang and Song, Yeon Han and Moon, Jong Ho and Lee, Yun Nah and Myeong, Jun Ho},
  title = {Removal of a broken percutaneous transhepatic biliary drainage catheter by cholangioscopy through a lumen-apposing metal stent used for choledochoduodenostomy},
  journal = {Endoscopy},
  year = {2023},
  volume = {55},
  number = {S 01 S 01},
  pages = {E373--E374},
  doi = {10.1055/a-1996-0223}
}