An observational study of contrast-enhanced ultrasound in diagnosing malignant breast masses
Polish Journal of Radiology · 20.04.2026 · 91 (1) · 169-178
DOI: 10.5114/pjr/218128 ↗Kurz gefasst
Fachartikel in der Zeitschrift Polish Journal of Radiology, online erschienen am 20.04.2026. Verfasst von Apurva Surana und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, All India Institute of Medical Sciences (AIIMS), Jodhpur, India. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To study the diagnostic role of contrast-enhanced ultrasound (CEUS) in terms of sensitivity, specificity, and its comparison with grey-scale ultrasound with colour Doppler in characterising malignant breast masses. Material and methods An observational study was done for duration of 18 months, including 64 adult females with breast masses. Patients underwent various investigations in the form of conventional ultrasound with colour Doppler and CEUS. Patients underwent surgery, and a histopathological examination was performed on a surgical specimen for confirmation of a benign or malignant lesion. Outcome measures were the proportion of benign and malignant lesions of the breast and the diagnostic accuracy of CEUS in characterising malignant lesions in the breast.
Results
On analysis, CEUS showed very good agreement with histopathological diagnosis with κ 0.967 (p < 0.0001); while good agreement was found between histopathological diagnosis and diagnosis by B mode + colour Doppler with κ 0.772 (p < 0.0001). CEUS demonstrated sensitivity of 100%, specificity of 96.15%, and AUC of 0.98, while diagnosis B mode + colour Doppler yielded sensitivity of 92.11%, specificity of 84.62%, and diagnostic accuracy of 89.06%.
Conclusions
CEUS was found to have a better diagnostic accuracy for differentiation of benign and malignant breast masses (using histopathology as a gold standard). The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy of CEUS was found to be 99%, 96%, 97.4%, 99%, and 98.4% respectively.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology, All India Institute of Medical Sciences (AIIMS), Jodhpur, India.
Zitieren
APA
Surana, A., & Johare, A. (2026). An observational study of contrast-enhanced ultrasound in diagnosing malignant breast masses. Polish Journal of Radiology, 91(1), 169-178. https://doi.org/10.5114/pjr/218128
Vancouver
Surana A, Johare A. An observational study of contrast-enhanced ultrasound in diagnosing malignant breast masses. Polish Journal of Radiology. 2026;91(1):169-178. doi:10.5114/pjr/218128
BibTeX
@article{Surana2026,
author = {Surana, Apurva and Johare, Akanksha},
title = {An observational study of contrast-enhanced ultrasound in diagnosing malignant breast masses},
journal = {Polish Journal of Radiology},
year = {2026},
volume = {91},
number = {1},
pages = {169--178},
doi = {10.5114/pjr/218128}
}
EUVIMED