EUVIMEDEUVIMED entdecken
Crossref

MAINTENANCE OF ETCO2 ON LOW FRESH GAS FLOW IN SPONTANEOUSLY BREATHING PEDIATRIC PATIENTS ON AYRE’S T-PIECE:A DESCRIPTIVE OBSERVATIONAL STUDY

Waseem Ismat Ch, Khalid Saeed Mirza, Tayyeba Aslam, Maryam Qayyum, Sidra Tul Muntaha H. Muzaffer, Amina Khalid Mirza

Journal of Akhtar Saeed Medical & Dental College · 30.06.2026 · 08 (02) · 98-104

DOI: 10.51127/jamdcv0802oa03 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Akhtar Saeed Medical & Dental College, online erschienen am 30.06.2026. Verfasst von Waseem Ismat Ch und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The Jackson Rees modified Ayre’s T-piece breathing system is widely used in pediatric anesthesia because of its low resistance and simple design. However, preventing carbon dioxide (CO₂) rebreathing in spontaneously breathing children typically requires high fresh gas flow (FGF), leading to increased volatile anesthetic consumption and environmental pollution. This study aimed to determine whether reducing FGF to match the patient’s minute ventilation (MV) could maintain adequate ventilation without causing CO₂ rebreathing. Materials and Methods: A descriptive observational study conducted on 25 pediatric patients undergoing general anesthesia for full mouth rehabilitation, with nasotracheal intubation, in Farooq Hospital, West Wood branch, Lahore, Pakistan. After initial high-flow ventilation, FGF was reduced to equal the estimated MV (Respiratory rate multiplied by Tidal volume (Vt), where Vt was taken as 10ml/kg). End-tidal CO₂ (EtCO₂), the level of CO2 released at the end of exhalation, indicating effective removal of CO₂, was noted every five minutes using capnography.

Results

The EtCO₂ values were not significantly affected by lowering FGF. Patients remained hemodynamically stable with no adverse respiratory events.

Conclusion

Matching FGF to MV in spontaneously breathing pediatric patients using the Ayre’s T-piece effectively prevents CO₂ rebreathing, ensures safe anesthesia, and significantly lowers environmental impact and resource consumption.

Zitieren

APA

Ch, W. I., Mirza, K. S., Aslam, T., Qayyum, M., Muzaffer, S. T. M. H., & Mirza, A. K. (2026). MAINTENANCE OF ETCO2 ON LOW FRESH GAS FLOW IN SPONTANEOUSLY BREATHING PEDIATRIC PATIENTS ON AYRE’S T-PIECE:A DESCRIPTIVE OBSERVATIONAL STUDY. Journal of Akhtar Saeed Medical & Dental College, 08(02), 98-104. https://doi.org/10.51127/jamdcv0802oa03

Vancouver

Ch WI, Mirza KS, Aslam T, Qayyum M, Muzaffer STMH, Mirza AK. MAINTENANCE OF ETCO2 ON LOW FRESH GAS FLOW IN SPONTANEOUSLY BREATHING PEDIATRIC PATIENTS ON AYRE’S T-PIECE:A DESCRIPTIVE OBSERVATIONAL STUDY. Journal of Akhtar Saeed Medical & Dental College. 2026;08(02):98-104. doi:10.51127/jamdcv0802oa03

BibTeX
@article{Ch2026,
  author = {Ch, Waseem Ismat and Mirza, Khalid Saeed and Aslam, Tayyeba and Qayyum, Maryam and Muzaffer, Sidra Tul Muntaha H. and Mirza, Amina Khalid},
  title = {MAINTENANCE OF ETCO2 ON LOW FRESH GAS FLOW IN SPONTANEOUSLY BREATHING PEDIATRIC PATIENTS ON AYRE’S T-PIECE:A DESCRIPTIVE OBSERVATIONAL STUDY},
  journal = {Journal of Akhtar Saeed Medical & Dental College},
  year = {2026},
  volume = {08},
  number = {02},
  pages = {98--104},
  doi = {10.51127/jamdcv0802oa03}
}