EUVIMEDEUVIMED entdecken
Crossref

Aerosol Delivery to Simulated Spontaneously Breathing Tracheostomized Adult Patients With Heated Humidified High Flow Oxygenation

Xiukai Chen, Fai A Albuainain, Jie Li

Respiratory Care · 2025-07 · 70 (7) · 873-878

DOI: 10.1089/respcare.12467 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Respiratory Care, online erschienen am 02.07.2025. Verfasst von Xiukai Chen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Dr. Chen, Mrs. Albuainain, and Dr. Li are affiliated with Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University, Chic…. Hauptthemen laut MEDLINE: Tracheostomy, Nebulizers and Vaporizers, Albuterol, Oxygen Inhalation Therapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Heated and humidified high-flow (HHHF) oxygen therapy is frequently used for spontaneous breathing tracheostomized patients. However, the efficacy of in-line placement of nebulizer via HHHF remains unclear. We aimed to assess the impact of nebulizer placements, flow settings, and interfaces on aerosol delivery using a vibrating mesh nebulizer with HHHF in a tracheostomized model.

Methods

A simulated spontaneous breathing model of a tracheostomized adult with tracheostomy tube size 8.0 mm was utilized. A collecting filter was placed between the tracheostomy tube and the model lung. Albuterol sulfate (2.5 mg/3 mL) was aerosolized via a vibrating mesh nebulizer in-line with HHHF (Airvo2). The aerosol delivery was evaluated with the nebulizer placed distally (near the humidifier) and proximally to the airway, using tracheostomy adapter and tracheostomy collar at gas flows of 15, 30, and 45 L/min. Each condition was tested five times. The drug was eluted from the collecting filter and assayed with ultraviolet spectrophotometry (276 nm).

Results

When delivering aerosol via an in-line vibrating mesh nebulizer with HHHF in a tracheostomized model, the inhaled dose increased as flow decreased, regardless of the interfaces and nebulizer placements (all P < .05). With the tracheostomy adapter, distal placement resulted in higher inhaled doses than the proximal placement at all flows (all P < .05). With the tracheostomy collar, inhaled doses were lower with distal placement than proximal placement, except at 15 L/min (21.3 ± 1.9 vs 16.4 ± 2.1%, P = .009). Compared with the tracheostomy adapter, the tracheostomy collar had higher inhaled doses with the vibrating mesh nebulizer placed proximally at 30 and 45 L/min but a lower inhaled dose with the vibrating mesh nebulizer placed distally at 30 L/min.

Conclusions

During aerosol delivery via in-line placement of vibrating mesh nebulizer with HHHF in a tracheostomized model, the inhaled dose increased as flow decreased. Distal nebulizer placement resulted in higher inhaled doses than proximal placement with the tracheostomy adapter at all flows and with the tracheostomy collar at 15 L/min.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TracheostomyNebulizers and VaporizersAlbuterolOxygen Inhalation TherapyBronchodilator AgentsHumansAerosolsAdultAdministration, InhalationModels, AnatomicHumidityRespirationEquipment DesignHot Temperature

Stichwörter der Autor:innen

aerosolheated and humidified high flownebulizer placementtracheostomyvibrating mesh nebulizer

Substanzen

AerosolsAlbuterolBronchodilator Agents

Autor:innen und Institutionen

  • Dr. Chen, Mrs. Albuainain, and Dr. Li are affiliated with Division of Respiratory Care, Department of Cardiopulmonary Sciences, Rush University, Chicago, Illinois, USA.
  • Dr. Chen is affiliated with Department of Critical Care Medicine, The First Affiliated Hospital of Xiamen University, Xiamen, China.
  • Mrs. Albuainain is affiliated with Department of Respiratory Care, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, Jubail, Saudi Arabia.

Zitieren

APA

Chen, X., Albuainain, F. A., & Li, J. (2025). Aerosol Delivery to Simulated Spontaneously Breathing Tracheostomized Adult Patients With Heated Humidified High Flow Oxygenation. Respiratory Care, 70(7), 873-878. https://doi.org/10.1089/respcare.12467

Vancouver

Chen X, Albuainain FA, Li J. Aerosol Delivery to Simulated Spontaneously Breathing Tracheostomized Adult Patients With Heated Humidified High Flow Oxygenation. Respiratory Care. 2025;70(7):873-878. doi:10.1089/respcare.12467

BibTeX
@article{Chen2025,
  author = {Chen, Xiukai and Albuainain, Fai A and Li, Jie},
  title = {Aerosol Delivery to Simulated Spontaneously Breathing Tracheostomized Adult Patients With Heated Humidified High Flow Oxygenation},
  journal = {Respiratory Care},
  year = {2025},
  volume = {70},
  number = {7},
  pages = {873--878},
  doi = {10.1089/respcare.12467}
}
Kostenlos starten →