EUVIMEDEUVIMED entdecken
Crossref

Evaluating the Effect of Adding Micro-hydroxyapatite and Nano-hydroxyapatite on the Microleakage and Fracture Resistance of Conventional and Resin-modified Glass Ionomer Cement

Himani Bhat, Purshottam Jasuja, Heena Khurana, Rudhra Koul, Suman Sharma

Dental Journal of Advance Studies · 12.05.2026 · 14 (1) · 27-32

DOI: 10.5005/djas-11014-0103 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Dental Journal of Advance Studies, online erschienen am 12.05.2026. Verfasst von Himani Bhat und 4 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

The aim of this in vitro study was to evaluate microleakage and fracture resistance of a mixture of conventional and resin-modified glass ionomer cement (RMGIC) with micro- and nano-hydroxyapatite (HAP). Materials and methods: In this in vitro study, 120 extracted non-carious human molars were prepared with standardized class I occlusal cavities and randomly allocated into six material groups: (1) conventional glass ionomer cement (CGIC), (2) CGIC + micro-HAP, (3) CGIC + nano-HAP, (4) RMGIC, (5) RMGIC + micro-HAP, and (6) RMGIC + nano-HAP. Teeth were thermocycled, coated with nail polish, except for restorations, apically sealed with sticky wax, and immersed in 2% basic fuchsin dye for 24 hours to assess microleakage. Teeth were sectioned, and dye penetration was scored. Fracture resistance was measured according to American Society for Testing and Materials (ASTM) E-399-90 using a transverse bending test. Microleakage data were analyzed with the Kruskal–Wallis test (p < 0.05), and fracture resistance differences were compared using one-way ANOVA (p < 0.05).

Results

The data analysis revealed that the HAP incorporation significantly reduced microleakage and increased fracture resistance of both CGIC and RMGIC (p < 0.001), while no statistically significant difference was observed between micro- and nano-HAP modified groups at 50% concentration.

Conclusion

It was concluded that incorporating both micro- and nano-sized HAP into RMGIC and CGIC effectively reduced microleakage. The addition of HAP to GIC enhances the fracture resistance.

Zitieren

APA

Bhat, H., Jasuja, P., Khurana, H., Koul, R., & Sharma, S. (2026). Evaluating the Effect of Adding Micro-hydroxyapatite and Nano-hydroxyapatite on the Microleakage and Fracture Resistance of Conventional and Resin-modified Glass Ionomer Cement. Dental Journal of Advance Studies, 14(1), 27-32. https://doi.org/10.5005/djas-11014-0103

Vancouver

Bhat H, Jasuja P, Khurana H, Koul R, Sharma S. Evaluating the Effect of Adding Micro-hydroxyapatite and Nano-hydroxyapatite on the Microleakage and Fracture Resistance of Conventional and Resin-modified Glass Ionomer Cement. Dental Journal of Advance Studies. 2026;14(1):27-32. doi:10.5005/djas-11014-0103

BibTeX
@article{Bhat2026,
  author = {Bhat, Himani and Jasuja, Purshottam and Khurana, Heena and Koul, Rudhra and Sharma, Suman},
  title = {Evaluating the Effect of Adding Micro-hydroxyapatite and Nano-hydroxyapatite on the Microleakage and Fracture Resistance of Conventional and Resin-modified Glass Ionomer Cement},
  journal = {Dental Journal of Advance Studies},
  year = {2026},
  volume = {14},
  number = {1},
  pages = {27--32},
  doi = {10.5005/djas-11014-0103}
}