EUVIMEDEUVIMED entdecken
Crossref

Antibacterial Activity of Conventional and Nano Hydroxyapatite Silica Glass Ionomer Cement (nanoHA-Silica-GIC) using Agar Diffusion Assay

Luddin N, Thiyagarajan G, Zulkifli SS, Hii SC, Abd Hamid IF

International Journal of Dentistry and Oral Health · 2026 · 12 (1)

DOI: 10.16966/2378-7090.438 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Dentistry and Oral Health, 2026. Verfasst von Luddin N und 4 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Dental caries remain a major public health issue, primarily caused by cariogenic bacteria such as Streptococcus mutans, Lactobacillus salivarius, and Enterococcus faecalis. Glass ionomer cements (GICs) are commonly used in restorative dentistry because of fluoride release and biocompatibility, while recent modifications incorporating nanomaterials aim to enhance their antibacterial property. This study evaluated the antibacterial efficacy of conventional and nano-modified GICs of Fuji IX (GC Japan), Fuji II LC Capsule (GC Japan), and nano hydroxyapatite-silica GIC (nanoHA-Silica-GIC) against S. mutans, L. salivarius, and E. faecalis using agar diffusion assay. Materials and methods: Meuller-Hinton blood agar (MHA) was used for bacterial growth, and inhibition zones were measured at 1, 3, 5, and 7 days. Statistical significance was assessed through one-way ANOVA and Kruskal-Wallis tests, with the threshold for significance set at (P < 0.05). All materials demonstrated antibacterial activity against the tested microorganisms.

Results

No difference (P > 0.05) was observed between Fuji IX and nanoHA-Silica-GIC. However, Fuji II LC showed the largest inhibition zones at all time intervals, with measurable differences (P < 0.05).

Conclusion

Within the study’s limitationof agar diffusion assay, nanoHA-Silica-GIC demonstrated antibacterial efficacy comparable to Fuji IX, while Fuji II LC produced larger inhibition zones against S. mutans, L. salivarius, and E. faecalis, which antibacterial efficacy possibly influenced by material diffusibility.

Zitieren

APA

N, L., G, T., SS, Z., SC, H., & IF, A. H. (2026). Antibacterial Activity of Conventional and Nano Hydroxyapatite Silica Glass Ionomer Cement (nanoHA-Silica-GIC) using Agar Diffusion Assay. International Journal of Dentistry and Oral Health, 12(1). https://doi.org/10.16966/2378-7090.438

Vancouver

N L, G T, SS Z, SC H, IF AH. Antibacterial Activity of Conventional and Nano Hydroxyapatite Silica Glass Ionomer Cement (nanoHA-Silica-GIC) using Agar Diffusion Assay. International Journal of Dentistry and Oral Health. 2026;12(1). doi:10.16966/2378-7090.438

BibTeX
@article{N2026,
  author = {N, Luddin and G, Thiyagarajan and SS, Zulkifli and SC, Hii and IF, Abd Hamid},
  title = {Antibacterial Activity of Conventional and Nano Hydroxyapatite Silica Glass Ionomer Cement (nanoHA-Silica-GIC) using Agar Diffusion Assay},
  journal = {International Journal of Dentistry and Oral Health},
  year = {2026},
  volume = {12},
  number = {1},
  doi = {10.16966/2378-7090.438}
}
Kostenlos starten →