One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device
Angiologia e Cirurgia Vascular · 2026 · 22 (1)
DOI: 10.48750/acv.689 ↗Kurz gefasst
Fachartikel in der Zeitschrift Angiologia e Cirurgia Vascular, 2026. Verfasst von Patrícia Carvalho und 7 weiteren Autor:innen.
Abstract (Originalsprache)
Background
The anatomical complexity of the aortic arch poses significant challenges to its repair, particularly in high-risk patients. The introduction of branched endografts, specifically designed to overcome these challenges, has revolutionized this field as demonstrated in the present case-report. Report: A 60-year-old male, with a prior history of smoking and neurosyphilis, was referenced to our outpatient clinic due to a CT finding of a 66mm aortic arch aneurysm with complex anatomical features, including a short brachiocephalic trunk and narrow iliac arteries. Thus, a staged hybrid approach was meticulously planned. The patient was initially submitted to a left carotid-subclavian bypass, followed by a right subclavian-carotid bypass. Later, an endoconduit was constructed using two GORE-Viabahn® stent grafts (11x100mm), deployed in the left common and external iliac arteries, facilitating subsequent TEVAR. Finally, the aneurysm was excluded using a custom-made Terumo-Relay® double inner-branched endograft (46x32x270mm) deployed in zone 0, with two inner branches for the brachiocephalic trunk (BCT)/right subclavian artery (RSA) and left common carotid artery (LCCA). The inner branches were catheterized via trans-carotid (left) and trans-axillary (right) accesses. An iliac extension GORE-Excluder® (16x12x100mm) to the BCT/RSA and a GORE-Viabahn® stent graft (7x75mm) to the LCCA were deployed. An additional extension endograft (34x30x150mm) was deployed to complete distal exclusion. The left subclavian artery was subsequently occluded using a vascular plug. Postoperatively, the patient experienced a minor posterior circulation stroke, with full recovery within two weeks. Six-month follow-up imaging showed patency of the endografts with complete exclusion of the aneurysm and no evidence of endoleaks. The patient remained asymptomatic, with no further vascular or neurological events.
Conclusion
This case highlights the feasibility of a staged hybrid approach for complex aortic arch aneurysms in patients with challenging anatomy. The use of a custom-made endograft and careful preoperative planning proved critical to the success of the procedure.
Schlagwörter
Zitieren
APA
Carvalho, P., Brandão, D., Fernandes, L., Machado, M., Basílio, F., Guimarães, B., Rocha, A. M., & Canedo, A. (2026). One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device. Angiologia e Cirurgia Vascular, 22(1). https://doi.org/10.48750/acv.689
Vancouver
Carvalho P, Brandão D, Fernandes L, Machado M, Basílio F, Guimarães B, et al. One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device. Angiologia e Cirurgia Vascular. 2026;22(1). doi:10.48750/acv.689
BibTeX
@article{Carvalho2026,
author = {Carvalho, Patrícia and Brandão, Daniel and Fernandes, Luís and Machado, Marta and Basílio, Francisco and Guimarães, Beatriz and Rocha, Ana Margarida and Canedo, Alexandra},
title = {One size does not fit all – Staged hybrid approach of a challenging aortic arch aneurysm using a double-branch custom-made device},
journal = {Angiologia e Cirurgia Vascular},
year = {2026},
volume = {22},
number = {1},
doi = {10.48750/acv.689}
}
EUVIMED