EUVIMEDEUVIMED entdecken
Crossref

Total endovascular aortic arch repair: a comprehensive review comparing parallel graft techniques and custom-made devices

Patrícia Carvalho, Daniel Brandão, Andreia Coelho, Luís Fernandes, Marta Machado, Francisco Basílio, Beatriz Guimarães, Ana Margarida Rocha, Alexandra Canedo

Angiologia e Cirurgia Vascular · 2026 · 21 (3)

DOI: 10.48750/acv.688 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Angiologia e Cirurgia Vascular, 2026. Verfasst von Patrícia Carvalho und 8 weiteren Autor:innen.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Endovascular approaches have emerged as promising alternatives for treating aortic arch pathology, particularly in high-risk patients. This review provides a comprehensive analysis of total endovascular aortic arch reconstruction, focusing on Parallel Graft Techniques (PGTs) and Custom-Made Devices (CMDs). METHODS: PubMed and Scopus were searched to conduct a comprehensive review comparing the technical aspects, clinical outcomes, strengths, and limitations of PGTs and CMDs. Only studies reporting on total endovascular aortic aneurysm repair were considered. Studies with fewer than five patients, published in a language other than Portuguese, English, or Spanish, and reporting hybrid/open procedures or partial aortic arch reconstructions were excluded. Findings were summarised descriptively. RESULTS: A total of 38 studies comprising 871 patients were included (214 in PGT and 657 in the CMD group). Technical success rates were high in both groups, mostly ranging from 80%80% to 100%100%. No clear superiority was observed between the two approaches for thirty-day, aorta-related, or overall mortality. However, stroke and spinal cord ischaemia (SCI) rates appeared higher in the CMD group, ranging from 0 to 42.9%42.9% and 0 to 9.1%9.1% respectively. The occurrence of type I and III endoleaks was higher in the PGT group (0-45.5% versus 0-32.4%), though this did not translate into a clear difference in reintervention rates. During follow-up, high target vessel patency rates were observed in both groups, typically exceeding 95%95% . CONCLUSION: PGTs appear to have non-inferior outcomes in terms of stroke rate and in-hospital and overall mortality. Although the occurrence of type I/III endoleaks remains higher in PGTs, this does not seem to affect reintervention rates. Thus, PGTs should be considered a viable option for treating complex aortic arch pathology, particularly in fragile patients, those with adverse anatomy, or in emergent situations. Large-volume prospective studies directly comparing these two techniques are currently warranted.

Schlagwörter

Endovascular Aneurysm Repair (MeSH)Aorta, Thoracic (MeSH)Aortic Arch Syndromes (MeSH)Stroke (MeSH)Endoleak (MeSH)

Zitieren

APA

Carvalho, P., Brandão, D., Coelho, A., Fernandes, L., Machado, M., Basílio, F., Guimarães, B., Rocha, A. M., & Canedo, A. (2026). Total endovascular aortic arch repair: a comprehensive review comparing parallel graft techniques and custom-made devices. Angiologia e Cirurgia Vascular, 21(3). https://doi.org/10.48750/acv.688

Vancouver

Carvalho P, Brandão D, Coelho A, Fernandes L, Machado M, Basílio F, et al. Total endovascular aortic arch repair: a comprehensive review comparing parallel graft techniques and custom-made devices. Angiologia e Cirurgia Vascular. 2026;21(3). doi:10.48750/acv.688

BibTeX
@article{Carvalho2026,
  author = {Carvalho, Patrícia and Brandão, Daniel and Coelho, Andreia and Fernandes, Luís and Machado, Marta and Basílio, Francisco and Guimarães, Beatriz and Rocha, Ana Margarida and Canedo, Alexandra},
  title = {Total endovascular aortic arch repair: a comprehensive review comparing parallel graft techniques and custom-made devices},
  journal = {Angiologia e Cirurgia Vascular},
  year = {2026},
  volume = {21},
  number = {3},
  doi = {10.48750/acv.688}
}
Kostenlos starten →