EUVIMEDScopri EUVIMED
Crossref

Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions.

Mustafa Borga Dönmez, A Fink, Münir Demirel, Türksayar, Almira Ada Diken, Ahmet Örgev, Gülce Çakmak, Yilmaz, Burak

Open Access CRIS of the University of Bern · 2025-11-01

DOI: 10.48620/90597 ↗

At a glance

Journal article in Open Access CRIS of the University of Bern, published on 2025-11-01. Written by Mustafa Borga Dönmez and 8 co-authors.

AbstractSubjectsDati bibliograficiCiteRelated studies

Abstract (original language)

Objective

To compare the dimensional stability of dentate, maxillary, bio-based resin casts with various base designs and storage conditions to that of casts in a dental resin.Material And Methods Dentate maxillary casts with either solid or hollow bases were additively manufactured using liquid crystal display technology from reference design files using a soy-based (EX), a corn-based (FD), and a dental cast (KM) resin (N = 20). Each set of casts was divided into two subgroups based on storage conditions (exposed to light or stored in light-proof boxes) (n = 10). Casts were digitized with a laboratory scanner the day after fabrication and weekly for the following four weeks. The scans were superimposed over their respective reference file to calculate region-based (anterior, posterior, entire arch, soft tissue, and entire cast) root mean square (RMS) values. Data were analyzed using a generalized linear model (α = 0.05).

Results

The RMS values were affected from the interactions among resin type, base design, and storage condition (P ≤ 0.018). Hollow-based KM casts stored in a light-proof box had the lowest anterior, posterior, and entire arch RMS, and mostly had lower overall RMS (P < 0.001). Hollow-based FD casts exposed to light mostly had lower soft tissue RMS (P ≤ 0.019).

Conclusions

Hollow-based KM casts stored in a light-proof box mostly had higher dimensional stability. However, the deviations observed across all casts remained within previously reported clinically acceptable thresholds for diagnostic and orthodontic applications.

Subjects

dimensional stabilitydental castsadditive manufacturingbio-based resinsstorage conditionslight exposuredental resin3D digitization

Cite

APA

Dönmez, M. B., Fink, A., Demirel, M., Türksayar, Diken, A. A., Örgev, A., Çakmak, G., Yilmaz, & Burak (2025). Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions. Open Access CRIS of the University of Bern. https://doi.org/10.48620/90597

Vancouver

Dönmez MB, Fink A, Demirel M, Türksayar, Diken AA, Örgev A, et al. Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions. Open Access CRIS of the University of Bern. 2025. doi:10.48620/90597

BibTeX
@article{Dnmez2025,
  author = {Dönmez, Mustafa Borga and Fink, A and Demirel, Münir and Türksayar and Diken, Almira Ada and Örgev, Ahmet and Çakmak, Gülce and Yilmaz and Burak},
  title = {Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions},
  journal = {Open Access CRIS of the University of Bern},
  year = {2025},
  doi = {10.48620/90597}
}
Start for free →