Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions.
Open Access CRIS of the University of Bern · 01.11.2025
DOI: 10.48620/90597 ↗Kurz gefasst
Fachartikel in der Zeitschrift Open Access CRIS of the University of Bern, erschienen am 01.11.2025. Verfasst von Mustafa Borga Dönmez und 8 weiteren Autor:innen.
Abstract (Originalsprache)
Objective
To compare the dimensional stability of dentate, maxillary, bio-based resin casts with various base designs and storage conditions to that of casts in a dental resin.Material And Methods Dentate maxillary casts with either solid or hollow bases were additively manufactured using liquid crystal display technology from reference design files using a soy-based (EX), a corn-based (FD), and a dental cast (KM) resin (N = 20). Each set of casts was divided into two subgroups based on storage conditions (exposed to light or stored in light-proof boxes) (n = 10). Casts were digitized with a laboratory scanner the day after fabrication and weekly for the following four weeks. The scans were superimposed over their respective reference file to calculate region-based (anterior, posterior, entire arch, soft tissue, and entire cast) root mean square (RMS) values. Data were analyzed using a generalized linear model (α = 0.05).
Results
The RMS values were affected from the interactions among resin type, base design, and storage condition (P ≤ 0.018). Hollow-based KM casts stored in a light-proof box had the lowest anterior, posterior, and entire arch RMS, and mostly had lower overall RMS (P < 0.001). Hollow-based FD casts exposed to light mostly had lower soft tissue RMS (P ≤ 0.019).
Conclusions
Hollow-based KM casts stored in a light-proof box mostly had higher dimensional stability. However, the deviations observed across all casts remained within previously reported clinically acceptable thresholds for diagnostic and orthodontic applications.
Schlagwörter
Zitieren
APA
Dönmez, M. B., Fink, A., Demirel, M., Türksayar, Diken, A. A., Örgev, A., Çakmak, G., Yilmaz, & Burak (2025). Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions. Open Access CRIS of the University of Bern. https://doi.org/10.48620/90597
Vancouver
Dönmez MB, Fink A, Demirel M, Türksayar, Diken AA, Örgev A, et al. Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions. Open Access CRIS of the University of Bern. 2025. doi:10.48620/90597
BibTeX
@article{Dnmez2025,
author = {Dönmez, Mustafa Borga and Fink, A and Demirel, Münir and Türksayar and Diken, Almira Ada and Örgev, Ahmet and Çakmak, Gülce and Yilmaz and Burak},
title = {Dimensional stability of additively manufactured dental casts in bio-based resins: Influence of cast base design and storage conditions},
journal = {Open Access CRIS of the University of Bern},
year = {2025},
doi = {10.48620/90597}
}
EUVIMED