Factors associated with intra-aortic balloon pump use in patients with left ventricular dysfunction after cardiac surgery at Hanoi Heart Hospital
Tạp chí Phẫu thuật Tim mạch và Lồng ngực Việt Nam · 09.11.2026 · 57-68
DOI: 10.47972/vjcts.vi.1943 ↗Kurz gefasst
Fachartikel in der Zeitschrift Tạp chí Phẫu thuật Tim mạch và Lồng ngực Việt Nam, online erschienen am 09.11.2026. Verfasst von Thi Thuc Phuong Vu und 2 weiteren Autor:innen.
Abstract (Originalsprache)
Low cardiac output syndrome in patients with reduced left ventricular systolic function undergoing cardiac surgery with cardiopulmonary bypass often requires hemodynamic support, and the intra-aortic balloon pump (IABP) is one of the commonly used mechanical circulatory support devices. Early identification of factors associated with IABP use may facilitate risk assessment and preparation of an appropriate circulatory support strategy for these patients.
Objective
To identify factors associated with the indication for intra-aortic balloon pump (IABP) use in patients with reduced left ventricular function undergoing cardiac surgery with cardiopulmonary bypass. Patients and Methods: This retrospective case–control study included 663 adult patients with a left ventricular ejection fraction (LVEF) 2 mmol/L (OR = 2.8; 95% CI: 1.8–4.5; p < 0.001), emergency surgery (OR = 1.8; 95% CI: 1.1–3.0; p = 0.028), and combined valvular and coronary artery surgery (OR = 1.6; 95% CI: 1.05–2.6; p = 0.036). Intensive care unit stay and total hospital stay were longer in the IABP group, whereas in-hospital mortality did not differ significantly between the two groups (4.3% vs. 4.2%; p = 0.979).
Conclusion
In patients with LVEF 2 mmol/L, emergency surgery, and combined valvular and coronary artery surgery were independently associated with IABP use.
Zitieren
APA
Vu, T. T. P., Tran, C. T., & Phan, V. H. (2026). Factors associated with intra-aortic balloon pump use in patients with left ventricular dysfunction after cardiac surgery at Hanoi Heart Hospital. Tạp chí Phẫu thuật Tim mạch và Lồng ngực Việt Nam, 57-68. https://doi.org/10.47972/vjcts.vi.1943
Vancouver
Vu TTP, Tran CT, Phan VH. Factors associated with intra-aortic balloon pump use in patients with left ventricular dysfunction after cardiac surgery at Hanoi Heart Hospital. Tạp chí Phẫu thuật Tim mạch và Lồng ngực Việt Nam. 2026:57-68. doi:10.47972/vjcts.vi.1943
BibTeX
@article{Vu2026,
author = {Vu, Thi Thuc Phuong and Tran, Cong Thanh and Phan, Van Hoc},
title = {Factors associated with intra-aortic balloon pump use in patients with left ventricular dysfunction after cardiac surgery at Hanoi Heart Hospital},
journal = {Tạp chí Phẫu thuật Tim mạch và Lồng ngực Việt Nam},
year = {2026},
pages = {57--68},
doi = {10.47972/vjcts.vi.1943}
}
EUVIMED